Coax cable loss: LMR-400, CNT-400, RG-58 and RG-213 compared

15 min read

Coax cable loss: LMR-400, CNT-400, RG-58 and RG-213 compared

LMR-400, CNT-400, RG-58 and RG-213 attenuation in dB per 100 m from 150 MHz to 5.8 GHz, a 20 m 4G worked example and when to step up a cable size.

The short answer: At 900 MHz (4G band 8), LMR-400 and CNT-400 both lose 12.8 dB per 100 m, RFI's RG213 about 21.4 dB and RFI's RG58C/U about 64.5 dB. Over a 20 m run at 700 MHz (4G band 28), about 60 per cent of the power arrives through LMR-400 or CNT-400, 43 per cent through RG-213 and 8 per cent through RG-58. LMR-400 and CNT-400 are the same 10.3 mm size, within 0.3 dB per 100 m of each other at every frequency, and take the same connectors. RG-213 is the same diameter with 1.6 to 2 times the loss. RG-58 suits a lead of a metre or two and nothing longer at 4G or Wi-Fi frequencies: from 1,800 MHz up it loses more than a decibel a metre.

What attenuation means, and why 3 dB is half the power

Attenuation is the signal power a cable turns into heat between one end and the other. Manufacturers state it in decibels (dB) per 100 m, or per 100 ft in the United States. A decibel is a ratio on a logarithmic scale: 1 dB of loss leaves 79 per cent of the power, 3 dB leaves half, 6 dB a quarter, 10 dB one tenth and 20 dB one hundredth. Loss adds up along the run, so a cable rated 12.8 dB per 100 m loses 2.56 dB over 20 m and 6.4 dB over 50 m.

Three things set the loss. The first is frequency: loss rises roughly with the square root of frequency, because current crowds into the surface of the conductors (the skin effect), plus a smaller term from the insulation that grows in direct proportion to frequency. Times Microwave prints this as a formula on the datasheet for LMR-400: attenuation in dB per 100 ft equals 0.122290 times the square root of the frequency in MHz, plus 0.000260 times the frequency. The second is conductor size: a 10 mm cable has a larger centre conductor and more shield than a 5 mm cable, so less resistance. The third is the dielectric, the insulation between centre conductor and shield: the foam polyethylene in LMR-400 and CNT-400 loses less than the solid polyethylene in RG-58 and RG-213.

Datasheet figures are nominal (typical for a new cable). A figure in dB per 100 ft converts to dB per 100 m by multiplying by 3.2808, because 100 m is 328.08 ft. RFI publishes its coaxial attenuation chart in dB per metre and dB per foot, so every RFI figure below is the per-metre figure times 100.

The four cables at a glance

LMR-400 is Times Microwave Systems' registered name for its 0.400 inch (10.29 mm) flexible low-loss cable. CNT-400 is CommScope's cable of the same size and construction, built to the same dimensions and taking the same 400-series connectors, which is why connectors are sold as "for CNT400 and LMR-400". RG-213 and RG-58 are old military designations for a solid polyethylene cable of a given size; many manufacturers make them, so the figures here are for the two RFI parts the Techwave Store stocks, RG213 (RFI 8213) and RG58C/U (RFI 8058), from RFI's datasheets and attenuation chart.

Cable LMR-400 (Times Microwave) CNT-400 (CommScope) RG-213 (RFI 8213) RG-58 (RFI 8058)
Outer diameter 10.29 mm 10.29 mm 10.30 mm 4.95 mm
Centre conductor solid copper-clad aluminium, 2.74 mm copper-clad aluminium, 2.74 mm stranded bare copper, 13 AWG stranded tinned copper, 19 x 0.18 mm (21 AWG)
Dielectric foam polyethylene foam polyethylene solid polyethylene solid polyethylene
Jacket UV-resistant polyethylene, black non-halogenated polyethylene, black PVC, black PVC, black
Operating temperature -40 to +85 °C -40 to +85 °C not stated not stated
Minimum bend radius 25.4 mm installed, 101.6 mm repeated flexing 25.4 mm (single bend) 127 mm 50.8 mm
Velocity of propagation 85 per cent 85 per cent 66 per cent 66 per cent
Highest frequency in the attenuation table 5,800 MHz 6,000 MHz 6,000 MHz 6,000 MHz

RFI charts both of its cables to 6,000 MHz, so the comparison below runs the full range, and the chart itself makes the point about size: at 1,800 MHz its RG58C/U reads 1.033 dB per metre, a decibel for every metre of cable, which is why RG-58 is a jumper and not a feeder at 4G, Wi-Fi or 5G frequencies.

Attenuation compared: dB per 100 m from 150 MHz to 5.8 GHz

The table gives attenuation in dB per 100 m at the frequencies Australian installers meet most often. Where the manufacturer prints a figure for that frequency it is quoted; otherwise it is computed from the manufacturer's own formula (LMR-400 at 700, 2,400 and 3,500 MHz) or interpolated between the two nearest printed frequencies and marked "about". RFI's chart runs from 200 to 6,000 MHz in 200 MHz steps, so its 450, 700, 900 and 3,500 MHz figures are interpolated; "not charted" means the frequency is below the chart's first point.

Grouped bar chart of attenuation in dB per 100 m for LMR-400, CNT-400, RFI RG213 and RFI RG58C/U at 450, 900, 1,800 and 3,500 MHz. LMR-400 and CNT-400 read 8.9, 12.8, 18.6 or 18.4, and 26.7 or about 26.8 dB; RG-213 about 14.1, about 21.4, 33.3 and about 52.3 dB; RG-58 about 41.4, about 64.5, 103.3 and about 167 dB, the last two above a red line at 100 dB per 100 m marked 1 dB per metre.
Figure 1. Attenuation per 100 m at four frequencies: LMR-400 and CNT-400 are within 0.3 dB of each other, RG-213 loses 1.6 to 2 times as much and RG-58 five to six times as much, passing 1 dB per metre at 1,800 MHz. Values marked ~ are interpolated between the manufacturer's neighbouring published frequencies. Source: Times Microwave LMR-400 datasheet, CommScope CNT-400 product page and RFI's coaxial attenuation chart (RG213 8213 and RG58C/U 8058), nominal values, read 1 and 8 November 2026.
Frequency Used for LMR-400 CNT-400 RG-213 (RFI 8213) RG-58 (RFI 8058)
150 MHz VHF land mobile and marine 5.0 4.9 not charted not charted
450 MHz UHF land mobile, UHF CB at 477 MHz 8.9 8.9 about 14.1 about 41.4
700 MHz 4G band 28 11.2 (formula) about 11.2 about 18.4 about 54.8
900 MHz 4G band 8 12.8 12.8 about 21.4 about 64.5
1,800 MHz 4G band 3 18.6 18.4 33.3 103.3
2,400 MHz Wi-Fi 2.4 GHz 21.7 (formula) 21.7 40.3 126.6
3,500 MHz 5G band n78 26.7 (formula) about 26.8 about 52.3 about 167
5,800 MHz Wi-Fi 5 GHz 35.5 35.8 74.8 244.3

LMR-400 and CNT-400 track each other within 0.3 dB per 100 m at every frequency, so for loss purposes they are the same cable. RG-213 is the same 10.3 mm diameter but loses 1.6 to 2.1 times as much, because of its solid dielectric and all-braid shield. RG-58 loses about five times as much as LMR-400 at 450 and 900 MHz and six to seven times as much at 3,500 and 5,800 MHz. For the VHF row, RFI's chart starts at 200 MHz, where RG213 reads 8.8 and RG58C/U 25.2 dB per 100 m.

One caution: RG-58 names a size, not a construction, and some cables sold as RG-58 use a foam dielectric. Nextivity's datasheet for its Cel-Fi cable assemblies lists an "RG58" at 35.00 dB per 100 m at 1 GHz, about half the loss of RFI's RG58C/U (69.1 dB at 1,000 MHz) and still two and a half times that of LMR-400, so ask for the part number behind any RG-58 figure.

A 20 m run at 700 MHz: what actually arrives

Take a common job: a 4G antenna on a roof, 20 m of cable down to a router or a Cel-Fi unit, on band 28 at 700 MHz, the band that reaches furthest into regional Australia.

Line chart of the power remaining along a 20 m cable run at 700 MHz, from the antenna at 100 per cent to the device, with the loss arithmetic beside each curve. LMR-400 or CNT-400 at 11.2 dB per 100 m times 0.2 loses 2.24 dB and 60 per cent arrives; RFI RG213 at 18.4 dB per 100 m loses 3.68 dB and 43 per cent arrives, crossing the half-power line at 16 m; RFI RG58C/U at 54.8 dB per 100 m loses 11.0 dB and 8 per cent arrives, crossing it at 5 m.
Figure 2. Power remaining along a 20 m run at 700 MHz (4G band 28), connectors not included: 60 per cent of the power reaches the device through LMR-400 or CNT-400, 43 per cent through RG-213 and 8 per cent through RG-58. The 50 per cent line is 3 dB of loss, the working limit; RG-58 reaches it at 5 m and RG-213 at 16 m. Computed by the three steps below from the attenuation at 700 MHz (Times Microwave LMR-400 formula, CommScope CNT-400, RFI chart for 8213 and 8058).
  1. Read the attenuation per 100 m at 700 MHz from the table: 11.2 dB for LMR-400 or CNT-400, 18.4 dB for RG-213 and 54.8 dB for RG-58.
  2. Multiply by the run length in hundreds of metres. For 20 m that is 0.2, which gives 2.24 dB, 3.68 dB and 11.0 dB.
  3. Convert the loss to a power fraction: divide the dB figure by 10, then raise 10 to the negative of that number. 2.24 dB gives 0.60, 3.68 dB gives 0.43 and 11.0 dB gives 0.080.
Cable Loss over 20 m at 700 MHz Power arriving
LMR-400 2.2 dB 60 per cent
CNT-400 2.2 dB 60 per cent
RG-213 3.7 dB 43 per cent
RG-58 11.0 dB 8 per cent

Add a connector at each end, about 0.3 dB for the pair, and the 400-size cable delivers about 56 per cent while RG-58 delivers about 7 per cent. The 8.7 dB between the two cables is a factor of more than seven in power, and it applies in both directions: a router that reports a reference signal received power (RSRP) of -100 dBm on the 400-size cable would report about -109 dBm on RG-58 with the same antenna. The same run on band 3 at 1,800 MHz loses 3.7 dB through LMR-400 (42 per cent arrives), 6.7 dB through RG-213 (22 per cent) and 20.7 dB through RG-58, which passes less than 1 per cent.

When to step up a cable size: the 3 dB rule

The working rule is to keep the run's loss, at the highest frequency the equipment uses, to about 3 dB or less, so that at least half the power survives the cable. Dividing 3 dB by the attenuation per metre gives the run length at which each cable reaches that limit.

Frequency LMR-400 or CNT-400 RG-213 RG-58
450 MHz 34 m about 21 m about 7 m
700 MHz 27 m about 16 m about 5 m
900 MHz 23 m about 14 m about 5 m
1,800 MHz 16 m 9 m 3 m
2,400 MHz 14 m 7 m 2 m
3,500 MHz 11 m about 6 m about 2 m
5,800 MHz 8 m 4 m 1 m

Read the table at the highest band the device will use: a 4G router that sits on band 28 at 700 MHz most of the day will be moved to band 3 at 1,800 MHz when the cell is busy, and a 5G router will use n78 at 3,500 MHz where it can. A 20 m run of 400-size cable is comfortable at 700 MHz (2.2 dB), acceptable at 1,800 MHz (3.7 dB) and over the limit at 3,500 MHz (5.3 dB).

When the run is longer than the table allows, the choices in order of preference are: shorten the cable by mounting the router or repeater close to the antenna and running Ethernet the rest of the way; step up to a 1/2 inch corrugated cable such as CommScope's LDF4-50A; or offset the loss with a higher-gain antenna, the weakest option because gain narrows the beam and does nothing for the uplink. Do not coil surplus cable to use up length: Nextivity's Cel-Fi GO quick start guide says the cable between the outdoor antenna and the unit "should be as short as possible".

Connectors, bend radius and outdoor rating

Every connector adds a little loss and, if fitted badly, a lot. A well-made N connector on 400-size cable adds in the order of 0.1 to 0.2 dB; count two per run, plus the same again for each adaptor. A crimp that has not gripped the braid or a centre pin that sits short shows up as a high standing wave ratio (signal reflected back towards the transmitter) that a cable change will not fix. 400-size cable takes N or 7-16 DIN connectors sized for its 2.74 mm centre conductor; RG-213 and RG-58 take their own sizes. A 4G router usually has SMA sockets, so a 400-size run ends in an N connector at the antenna and an N-to-SMA adaptor or a short SMA jumper at the router.

Bend radius is where RG-213 and the 400-size cables part company. Times Microwave gives LMR-400 a 25.4 mm minimum bend radius for installation and 101.6 mm for repeated flexing; CommScope gives CNT-400 25.4 mm for a single bend; RFI's chart gives RG213 127 mm and RG58C/U 50.8 mm. Bend any of them tighter than the datasheet figure and the foam or braid deforms, raising loss at that point for good.

Outdoor rating comes down to the jacket. Times Microwave states that standard LMR-400 has a UV-resistant polyethylene jacket and "life expectancy in excess of 20 years", lists it as outdoor rated, and sells a separate LMR-400-DB for direct burial with a watertight braid. CommScope lists CNT-400 with a black non-halogenated polyethylene jacket and an operating range of -40 to +85 °C; its product page does not state a UV rating, so ask for the specification sheet if the run will sit in full sun. RFI's datasheets for RG213 and RG58C/U give a black PVC jacket and no UV, outdoor or burial rating, so ask before either goes into full sun or the ground. Whichever cable is used, every outdoor connector needs sealing; Nextivity's guide says to use sealant on any connections exposed to the elements.

Why Cel-Fi and 4G router installations specify 400-size cable

A mobile repeater or a 4G router has one resource it cannot make more of: the signal that arrives from the tower. A Cel-Fi unit amplifies what reaches its donor port, and a router with a weak signal falls back to slower data rates and spends more transmit power on the uplink. Cable loss comes straight off that resource, on the downlink and the uplink.

The tables above make the choice. A 20 m run to a roof antenna loses 2.2 dB through 400-size cable at 700 MHz and 11.0 dB through solid-dielectric RG-58, and that 8.7 dB turns a usable signal into a marginal one. Nextivity supplies RG58, LMR195 and LMR240 assemblies for its GO G41, GO G51 and CONNECT C41 units in lengths of 10 to 25 m, which suit vehicles, where the run is short and the cable must thread through a cabin. For a building, where the donor antenna sits on a roof and the unit in a cupboard two floors down, installers specify 400-size cable because at those lengths it is the only cable in the table that keeps the loss near 3 dB across the 4G bands. That is why a Cel-Fi quote, a mine-site router installation or a farm 4G setup normally reads "CNT-400" or "LMR-400".

The Techwave Store stocks CommScope CNT-400 by the reel, including a 100 m reel, made-up Pulse CNT400 N-male to N-male leads such as the 20 m lead, and 400-series connectors such as the Pulse N-205 N-male, which fits CNT-400 and LMR-400 alike. For a short VHF or UHF jumper the store carries RFI RG213 and RFI RG58C/U by the 100 m reel.

How to use a cable loss calculator

A cable loss calculator takes the cable type, run length, frequency and number of connectors and returns the total loss in dB and the share of power that arrives. Enter the highest frequency the equipment will use, the length you will actually install including the vertical drop and the slack at each end, and two connectors plus one for every adaptor. Check that the calculator names the cable part it uses ("RG-58" could be solid or foam dielectric) and compare its 900 MHz figure with the manufacturer's table. A calculator built on the datasheet figures in this article is coming to the Techwave Store; until then the three-step method above gives the same answer.

Frequently asked questions

Is LMR-400 the same as CNT-400?

They are two manufacturers' cables of the same 0.400 inch (10.29 mm) size and construction: a 2.74 mm copper-clad aluminium centre conductor, foam polyethylene dielectric, aluminium tape and tinned copper braid, and a black polyethylene jacket. Their published attenuation is within 0.3 dB per 100 m at every frequency from 150 to 5,800 MHz, and they take the same 400-series connectors. LMR is a Times Microwave registered name and CNT is CommScope's, so a specification that says "LMR-400 or equivalent" is met by CNT-400.

Can I use RG-58 for a 4G antenna?

Only as a short lead. At 700 MHz RFI's RG58C/U loses about 54.8 dB per 100 m, so a 5 m lead loses about 2.7 dB and a 20 m run loses 11.0 dB, leaving 8 per cent of the power. On band 3 at 1,800 MHz it loses 103.3 dB per 100 m, a decibel a metre, so the same 20 m run passes less than 1 per cent.

How long can a coax run be?

As long as the loss at the highest frequency you use stays near 3 dB, which is half the power. For LMR-400 or CNT-400 that is about 27 m at 700 MHz, 16 m at 1,800 MHz and 11 m at 3,500 MHz; for RG-213 about 16, 9 and 6 m; for solid-dielectric RG-58 about 5 m at 700 MHz and 3 m at 1,800 MHz. Beyond that, shorten the route, step up a size or mount the device closer to the antenna.

Does cable loss matter for receive?

Yes, by the same number of decibels. A run that loses 11.0 dB on transmit also delivers 11.0 dB less of the tower's signal to the router, and the router's own noise does not change, so its signal-to-noise ratio falls by the same amount. On a 4G router this shows up as a lower RSRP and a lower data rate.

Is RG-213 better than RG-58?

For loss, yes: RG-213 loses about a third as much (about 21.4 against 64.5 dB per 100 m at 900 MHz; 33.3 against 103.3 at 1,800 MHz). Against a 400-size cable of the same diameter it is the poorer choice, with 1.6 to 2.1 times the loss, a 127 mm bend radius and a PVC jacket.

How do I convert dB per 100 ft to dB per 100 m?

Multiply by 3.2808, because 100 m is 328.08 ft. The other way, divide by 3.2808. A chart in dB per metre, like RFI's, is simpler: multiply by 100, so RG213's 0.228 dB per metre at 1,000 MHz is 22.8 dB per 100 m. Times Microwave prints both columns from unrounded data, so its dB per 100 m figure can differ by 0.1 dB from a conversion of the printed dB per 100 ft figure, and RFI's per-foot column rounds the same way.

Talk to us about cable and connectors

The Techwave Store carries CommScope CNT-400 by the reel and in made-up N-male leads, RFI RG213 and RG58C/U by the reel, and the matching Pulse, RFI and CommScope connectors and crimp tools. Browse the coaxial cables collection, or send us the antenna, the device, the bands and the run length and we will tell you which cable and connectors the job needs.

The datasheets and product pages linked in this article were read on 1 and 8 November 2026; specifications change, so check the current datasheet before you order.


Footer image

© 2006 Techwave Pty Ltd. All rights reserved.

  • AU (AUD $) AU (AUD $)
  • American Express
  • Apple Pay
  • Google Pay
  • Mastercard
  • PayPal
  • Union Pay
  • Visa