Subscribe to Techwave Spotlight
Stay updated on tech trends, product launches and exclusive offers! Read our Policy Policy.
How to install a Cel-Fi GO G41, GO G51 or ROAM R41: antennas, cable by length, splitters, two carriers, multi-storey buildings and worked designs.
A Cel-Fi repeater is only as good as its installation. The unit has up to 100 dB of gain, and the antennas and cable around it decide how much of that reaches the phones. This guide covers the parts of a system, the installation of a GO G41 or GO G51 step by step, how far one server antenna covers and when to add another, splitters, couplers and cable lengths, two carriers on one site, buildings of several floors, worked designs with their loss budgets, and the ROAM R41 in vehicles and boats.
Donor antenna high and aimed. The lowest-loss cable the run justifies. Server antennas far from the donor. Split only a strong system.
If you have not yet chosen a unit, start with Cel-Fi GO G41, GO G51 or ROAM R41: which repeater for your site. Whichever you fit, it may only be switched on with the carrier's written permission; the law is set out in that article.
A fixed Cel-Fi GO system has six kinds of part: the donor antenna outside, facing the base station; its mount; the unit; the server antenna or antennas inside, serving the phones; a splitter when there is more than one server antenna; and the coaxial cable that joins them. The unit's two ports are SMA female, and every cable, splitter and antenna must be 50 ohm. Television coax and F-type connectors are 75 ohm and do not belong in the system.

| Part | Job | On the Techwave Store |
|---|---|---|
| Donor antenna | Receives the carrier's signal outside and sends the phones' signal back | LPDA7038, LPDA7040 mini LPDA, YW15-6989 Yagi, COL8199 |
| Mount | Holds the donor antenna above the roofline | Mast or J-pole, with a clamp to suit the pole |
| Cel-Fi GO unit | Amplifies one carrier's channels in both directions | G41 packs, G41 packs for Vodafone, G51 packs |
| Coaxial cable | Joins antennas, unit and splitters; 50 ohm throughout | RFI 9006, CNT-400, LDF4-50A |
| Connectors and adaptors | Fit the cable to the unit's SMA ports and the antennas' N tails | Pulse N-201, L4TNM-PSA, Pulse A-74 |
| Splitter, coupler or combiner | Shares the signal between server antennas, or joins two units | Wilkinson splitter, power divider, hybrid combiner |
| Server antenna | Covers the area where the phones are | Ceiling dome, low-profile ceiling antenna, wall panel |
| Protection | Keeps water and surges out | Weatherproofing kit, surge protector |
Walk the outside of the building with a phone on the carrier you want to repeat and find the spot with the best signal quality. The G41 quick start guide sums up where to look: "Outdoors, higher up, and away from the server antenna is best." The system needs at least one bar of native signal somewhere outside, and a donor signal as weak as about -120 dBm can be enough. Note the direction the signal comes from, because that is where a directional antenna will point.
A directional donor antenna is the usual choice: higher gain and less interference than an omni, at the cost of having to aim it.
| Donor antenna | Type and gain | Connection | Use it when |
|---|---|---|---|
| RFI LPDA7038 | Log periodic: 10.8 dBi at 698 to 960 MHz, 11 dBi at 1,710 to 2,700 MHz, 2.3 dBi at 3,400 to 3,800 MHz | Fitted 10 m lead with SMA male, or a 0.5 m tail with N female | The standard choice for a G41 on 4G |
| RFI LPDA7040 mini LPDA | Enclosed log periodic: 9.5 dBi at 698 to 960 MHz, 11 dBi at 1,710 to 2,700 MHz, 11.5 dBi at 3,300 to 4,000 MHz | 0.3 m tail with N female | The choice for a G51 on band n78, and the neater antenna on a house |
| RFI YW15-6989 | 15-element Yagi, 698 to 890 MHz only, 13 dBd | N female tail | A weak 700 or 850 MHz signal a long way from the tower |
| RFI COL8199 | Omnidirectional collinear, 8.5 dBi | Fitted 10 m lead with SMA male | Where a directional antenna cannot be aimed at one tower |
Read the 3,400 to 3,800 MHz figures before buying a G51. The LPDA7038 is an 11 dBi antenna on the 4G bands and a 2.3 dBi antenna on band n78, by its own datasheet, while the LPDA7040 holds 11.5 dBi there. A G51 bought for 3.5 GHz 5G should have the mini LPDA, which is why the Store's G51 packs offer a "Mini-LPDA" option.
Mount the antenna on a mast or an eave-mounted J-pole, clear of the roofline, with its elements vertical. Form a drip loop in the cable below the antenna, seal every outdoor connector with a weatherproofing kit, and on an exposed mast fit a surge protector such as the PolyPhaser GT-NFF-AL where the cable enters the building, bonded to earth.
A three-step rule covers most runs. Runs under about 10 m can use 9006, RFI's low-loss cable in the RG58 size. Runs of 10 to 25 m should be CNT-400. Runs over 25 m should move to CommScope's LDF4-50A, a 1/2 inch corrugated cable that is stiffer and needs someone with the skill to fit its connectors.
The table puts numbers on that rule for the three bands that matter: 900 MHz for the low bands, 1,800 MHz for the mid bands and 3,600 MHz for band n78. The 9006 figures are from the maker's attenuation chart, with 900 MHz interpolated between the printed 800 and 1,000 MHz values. The CNT-400 figures are from Andrew's CNT-400 page, with 3,600 MHz interpolated between 3,000 and 4,000 MHz. The LDF4-50A figures are from Andrew's LDF4-50A page, using its 894 MHz value for 900 MHz.
| Run | RFI 9006 (5 mm): 900 / 1,800 / 3,600 MHz | CNT-400 (10.3 mm): 900 / 1,800 / 3,600 MHz | LDF4-50A (1/2 inch): 900 / 1,800 / 3,600 MHz | Our pick |
|---|---|---|---|---|
| 5 m | 1.8 / 2.6 / 3.8 dB | 0.6 / 0.9 / 1.4 dB | 0.3 / 0.5 / 0.7 dB | 9006 lead for 4G; CNT-400 for n78 |
| 10 m | 3.6 / 5.2 / 7.6 dB | 1.3 / 1.8 / 2.7 dB | 0.7 / 1.0 / 1.5 dB | 9006 is acceptable for 4G by the three-step rule; CNT-400 is our pick |
| 15 m | 5.5 / 7.9 / 11.4 dB | 1.9 / 2.8 / 4.1 dB | 1.0 / 1.5 / 2.2 dB | CNT-400 |
| 20 m | 7.3 / 10.5 / 15.2 dB | 2.6 / 3.7 / 5.4 dB | 1.4 / 2.0 / 3.0 dB | CNT-400 for 4G; LDF4-50A for n78 |
| 25 m | 9.1 / 13.1 / 18.9 dB | 3.2 / 4.6 / 6.8 dB | 1.7 / 2.5 / 3.7 dB | CNT-400 by the three-step rule; LDF4-50A for n78 or a weak donor signal |
| 30 m | Not suggested | 3.8 / 5.5 / 8.1 dB | 2.1 / 3.0 / 4.5 dB | LDF4-50A |
| 40 m | Not suggested | 5.1 / 7.4 / 10.9 dB | 2.7 / 4.0 / 6.0 dB | LDF4-50A; shorten the run for n78 |
| 50 m | Not suggested | 6.4 / 9.2 / 13.6 dB | 3.4 / 5.0 / 7.4 dB | LDF4-50A for 4G; too long for n78, move the unit closer |
Cable loss counts twice: every decibel lost in the donor cable is a decibel less signal reaching the unit and a decibel less uplink power leaving the antenna, and every decibel lost in the server cable shrinks the coverage indoors. Three decibels is half the power. Our picks aim to keep each run near 3 dB or less at the highest band it carries, and follow the three-step rule where the two differ by little. The 3 dB threshold is our judgement, not a manufacturer's rule.
The 3,600 MHz column is why a G51 needs better cable than a G41 over the same distance. On a 15 m run, 9006 loses 11.4 dB at 3,600 MHz, CNT-400 loses 4.1 dB and LDF4-50A loses 2.2 dB. Nextivity ships a 10 m RG58 or LMR195 lead in some G51 kits, which suits those kits' own antennas; for a roof run, use the heavier cable.
All three cables are on the Store: RFI 9006 by the metre, CNT-400 by the metre and on 50 m and 100 m reels, and LDF4-50A by the metre.
| Join | Parts |
|---|---|
| Unit port (SMA female) to an N-type cable | Pulse A-74 SMA male to N female adaptor, or a Pulse SMA male to N male lead of 0.5 m to 20 m |
| The ends of a CNT-400 run | Pulse N-201 N male and Pulse N-200 N female crimp connectors, fitted with the RCT-214 crimp tool; or ready-made N male to N male leads of 10 m, 15 m and 20 m |
| The ends of an LDF4-50A run | CommScope L4TNM-PSA N male and L4TNF-PSA N female, with the cable prepared by the MCPT-L4 tool |
| The ends of a 9006 run | Pulse N-88 N male and Pulse N-98 N female crimp connectors |
| Two N male leads end to end | Pulse N-10 N female to N female adaptor |
| Antenna tails | N female on the LPDA7038 0.5 m version, the LPDA7040, the ceiling domes and the DAS panel, so the cable end is N male. Antennas with a fitted lead (LPDA7038 10 m version, COL8199, CPL6938) end in SMA male and screw straight onto the unit |
LDF4-50A does not bend into the back of a wall-mounted unit. Finish each end of a 1/2 inch run with a short flexible SMA to N lead.
The placement rule has two parts. An omnidirectional antenna covers all round and belongs in the centre of the area. A panel covers the area in front of it, has more gain, and belongs on a side wall pointing in, which is often easier to cable than a ceiling.
| Server antenna | Pattern | Fixing and connection | Use it for |
|---|---|---|---|
| RFI DAS6938-SOC150-N | Omnidirectional ceiling dome | Through a ceiling tile; 300 mm tail with N female; IP45 | The centre of an open room or office |
| RFI DAS6940LC-SOC150-N | Low-profile omnidirectional ceiling antenna | Through a ceiling tile; 300 mm tail with N female | Where a dome would be too visible |
| RFI DAS6938-SDP150-N | Directional panel, 5 to 7 dBi by band | Wall; 300 mm tail with N female; IP55 | A long room, a corridor, a shed bay or an outdoor area |
| RFI CPL6938 | Directional panel | Wall; fitted 10 m lead with SMA male | A quick installation with no connectors to fit |
| RFI CSM700 | Compact omnidirectional | Small wall bracket | A single room where a ceiling antenna cannot go |
The unit can amplify by up to 100 dB, so if the server antenna's output leaks back into the donor antenna the unit has to wind its gain down, and coverage shrinks with it. The G51 quick start guide puts the server antenna as far from the donor antenna as the cable allows, "with at least one wall separating them". The G41 guide says the same thing in other words: distance, walls and floors all count as isolation, and vertical separation generally isolates better. In a steel shed, point the donor antenna away from the shed and put the server antenna at the far end.
Both fixed units are indoor equipment, rated IPX0 and 0 to 40 °C: mount the unit on a wall in a dry, ventilated place within reach of a power point. Connect both antennas before power. Then use the Nextivity WAVE App over Bluetooth to choose the carrier and check the system; the G51 guide says to pick the carrier in App Settings if the unit is not already set for it. For a site you will not visit often, plug the unit's Ethernet port into an internet connection so the installer can watch it in the WAVE Portal. A small 4G router does that job, such as the Robustel R1511 and R1520.
Register before use. A newly installed Cel-Fi unit has to be registered before it goes into service. Registration is done in the Nextivity WAVE App, which Nextivity describes as the platform used to activate its products: connect to the unit over Bluetooth and follow the app's registration steps. Do it on the day, while you are still on site.
Keep the software current. Nextivity releases software updates for these units, and some of them are essential to the way the unit works, so apply each update when it is offered instead of putting it off. Updates are managed through WAVE, and an installer can also load them through the unit's Ethernet or USB port with Nextivity's field tool. Check for an update on the day of installation, and again whenever the unit raises an alarm.
Nextivity's current datasheets give no coverage radius, and no single figure fits every building. A workable starting point is a coverage bubble with a radius of about 20 m where the internal walls are timber-framed, less where they are concrete, and more than 65 m in an open commercial space.
Three things change the radius:
From those, these are our working spacings for planning, to be confirmed by a walk test:
| Building | One ceiling dome covers about | Space two domes about | Notes |
|---|---|---|---|
| House, office or shop with timber-framed or plasterboard walls | 20 m radius | 25 to 35 m apart | The two areas should overlap by a few metres |
| Brick or concrete internal walls | One or two rooms | One antenna per walled zone, often 10 to 15 m apart | Corridors that open onto the rooms are good positions |
| Open shed, workshop or warehouse floor | 65 m radius or more | 60 to 100 m apart | Racking full of stock behaves like walls; a panel at each end of an aisle is often better |
| High roof, 8 m or more | Less at floor level than the figures above | Use panels on walls or columns, aimed along the floor | A dome's pattern is meant for an ordinary ceiling height |
These are planning figures, not guarantees, and the spacings and notes are our judgement.
Add a second antenna when the far end of the area is still weak with the unit at full output. The test is simple. With the system running, stand at the edge of the area with a phone on that carrier. If calls and data are solid, stop. If the phone is back to one bar, or its field-test screen shows a signal weaker than about -100 dBm, a second antenna is the fix, placed so that its area overlaps the first. There is no gain control to turn up, because the unit sets its own gain. Two domes closer than about 10 m in open space mostly cover the same floor twice.
There is no minimum distance between two server antennas for the system's sake, since they carry the same signal. The distance that matters is the one from each server antenna back to the donor antenna.
One server antenna is the starting point, not the limit. The G51 quick start guide shows three layouts, one server antenna, two through a splitter, and four through a splitter for a multi-storey building, and Nextivity's G51 page adds a fourth with two units sharing one donor antenna. The same layouts apply to a G41 on its 4G channels.

| Layout | Splitter | Most power each antenna can receive, before cable loss | Suits |
|---|---|---|---|
| A. One server antenna | None | 20 dBm on a 4G channel, 27 dBm on n78 | One open space |
| B. Two server antennas | Two-way, up to 3.6 dB | 16.4 dBm on 4G, 23.4 dBm on n78 | A long building or two rooms |
| C. Four server antennas | Four-way, up to 6.9 dB | 13.1 dBm on 4G, 20.1 dBm on n78 | One antenna per floor or zone |
| D. Ceiling dome plus outdoor panel | Two-way, up to 3.6 dB | As layout B | A shop floor plus a dock or yard |
| E. Two units on one donor antenna | Two-way on the donor side, then as B for each unit | As layout B for each unit | Two carriers on one roof antenna, or two floors |
The splitter figures are the split loss plus the maximum insertion loss on Pulse's Wilkinson datasheet: 3 dB plus 0.6 dB for the two-way, 6 dB plus 0.9 dB for the four-way. The power figures are the units' maximum output less that loss. A unit only reaches its maximum when the donor signal is strong enough: The arithmetic is donor signal plus gain, so a -90 dBm carrier and 100 dB of gain give +10 dBm.
That arithmetic is behind the three rules in the G51 guide's advanced installation page:
In plain terms: do not split a weak system. If the unit is only producing a few milliwatts because the donor signal is poor, improve the donor side first, with a better antenna position, a higher-gain antenna or lower-loss cable, and split afterwards.
Two kinds of splitter are sold for this band, and they differ in the property Nextivity asks for.
For a G51 we follow Nextivity's guide and fit the Wilkinson type. For four antennas, the four-way's 18 dB rating sits just under Nextivity's figure, so a tree of three two-way units, each rated at 20 dB, is the closer match at a cost of up to 7.2 dB instead of 6.9 dB. Power dividers suit several server antennas at similar distances from one unit. Directional couplers, such as the Pulse PSP6927-2310-N for the G41's bands, suit antennas at different distances that need unequal shares.
A splitter gives each output the same share, so it suits antennas whose cables lose about the same. The lengths never have to match for timing: 30 m of cable delays the signal by roughly a tenth of a microsecond, far inside the few microseconds that 4G and 5G signals are built to tolerate. What matters is the difference in loss. Our rule is to keep the legs of an equal split within about 3 dB of each other, which at 1,800 MHz is about 16 m of CNT-400 or 30 m of LDF4-50A, and at 3,600 MHz about 11 m and 20 m.
When the legs differ by more than that, there are three fixes, in order of preference:
| A near antenna on 5 m and a far antenna on 40 m of CNT-400, at 1,800 MHz | Loss to the near antenna | Loss to the far antenna | Difference |
|---|---|---|---|
| Two-way splitter, up to 3.6 dB each way | 4.5 dB | 11.0 dB | 6.5 dB |
| 6 dB coupler: 6 dB to the coupled port, about 1.3 dB through | 6.9 dB | 8.6 dB | 1.7 dB |
| 10 dB coupler: 10 dB to the coupled port, about 0.5 dB through | 10.9 dB | 7.8 dB | 3.1 dB, now favouring the far antenna |
The coupler figures are the ideal values for a lossless coupler; a real one adds a few tenths of a decibel. A row of antennas along a corridor or up a riser uses the same idea repeated: a coupler at each antenna, with the coupling value falling towards the end of the line, and a two-way splitter for the last two. On the Store, the Pulse PSP6927-2310-N is a 10 dB coupler for the G41's bands, and the CommScope C-6-UW-N-AI6 and C-10-UW-N-AI6 are 6 dB and 10 dB couplers rated to 6,000 MHz, which suits a G51.
Layout D answers a common request: coverage on the shop or warehouse floor and on the loading dock or yard outside. Split the server side two ways. One leg goes to a ceiling dome over the floor. The other goes to a DAS6938-SDP150-N panel, which is IP55 rated, fixed to the outside wall and aimed across the outdoor area. Three points matter more than usual:
Layout E puts a two-way splitter between one donor antenna and two units. It suits a site that needs two carriers and has room for only one roof antenna, provided both carriers' towers lie in roughly the same direction, or two floors that each need a unit's full output. The part matters: when Cel-Fi units are combined, the combiner must have high isolation between its ports, which means a Wilkinson splitter/combiner or a hybrid combiner, not a reactive divider. Talk to us before ordering this layout. Pulse rates its Wilkinson units at 0.25 W when combining, which is the G51's maximum uplink power on n78, so the power, the losses and the isolation all need checking for the site.
A GO relays one carrier at a time, so Telstra and Optus together means two units: two G41s, two G51s, or one of each, with each carrier's permission for its own unit. One unit cannot do both. Set to one carrier, it ignores the other's channels.
The donor side. Give each unit its own donor antenna, aimed at its own carrier's tower, and mount the two antennas apart on the mast or the roof. Each unit then receives its full signal. One shared donor antenna is possible when both towers lie in the same direction, as in layout E above, but it costs each unit more than 3 dB in both directions and it needs a high-isolation splitter.
The server side. The two units can share one set of indoor antennas. The part for the job is a 2x2 hybrid combiner: the two units connect to its two inputs, and each of its two outputs carries both carriers. Nothing is thrown away when both outputs are used, each feeding a server antenna. The Pulse PSP6938-2203-N covers 698 to 3,800 MHz with a coupling loss of 3.05 dB, give or take 0.8 dB, and at least 22 dB of isolation between the two units, which meets Nextivity's 20 dB figure. The PSP6927-2203-N is the 698 to 2,700 MHz version for two G41s. If only one server antenna is wanted, the unused output must be closed with a 50 ohm termination, and half the power is lost in it, so a second antenna is the better use of that port. Each output can be split again in the usual way.
| Two G41s, one per carrier, through a 2x2 hybrid to two ceiling domes | At 1,800 MHz |
|---|---|
| Maximum output of each unit | 20 dBm |
| Hybrid combiner, at most | 3.85 dB |
| 10 m of CNT-400 to each dome | 1.8 dB |
| Each carrier at each dome, at most | 14.3 dBm |
The rule for the part is the one given above: units are combined through high-isolation devices, Wilkinson or hybrid, while reactive power dividers are for splitting only. A site that wants both units watched remotely needs a network port for each, and a small 4G router with several Ethernet ports, such as the Robustel R1520, provides them.

For a bigger building, the other answer to two carriers is a QUATRA system, described next.
Take a ten-storey building with weak signal on every floor. There are three ways to attempt it.
| Design | What each floor gets | Verdict |
|---|---|---|
| One GO in the plant room, split ten ways up a riser | A ten-way split is 10 dB before insertion loss, and the riser adds more. From 20 dBm, the floors see roughly 4 to 8 dBm for a single antenna, a quarter or less of the open-space reach of an unsplit unit | Too thin. Sound for two floors, marginal for four |
| One GO per floor, sharing a donor antenna | Full output on each floor, but the donor signal is split ten ways too, which weakens what each unit hears and what it sends back. Ten units to authorise, power and watch | Workable for two or three floors, not for ten |
| QUATRA: a powered Coverage Unit on each floor | Each Coverage Unit is a powered radio fed over category cable, so there is no coax loss between floors | The design for this building |
QUATRA is Nextivity's system for sites that outgrow a GO: buildings of many floors, large floor plates, and groups of buildings such as a hospital or a school campus. Instead of sending the signal down long coaxial runs, it puts a powered Coverage Unit on each floor, fed from a central Network Unit over category cable, with optical fibre between buildings. It also comes in versions for more than one carrier. This guide does not go into QUATRA design. If your site is in that class, talk to us and we will scope it from floor plans and a signal survey.

Between the two sits the building of two or three floors, where a GO still makes sense:
Ask us before ordering parts for anything above three floors.
Every level below is a maximum at the antenna port: the unit's maximum output less the splitter and cable losses from the tables above. A unit reaches its maximum only with a good donor signal.
| Part | Choice | Loss or level |
|---|---|---|
| Unit | G41 "LPDA + Dome" pack | 20 dBm maximum |
| Donor run | LPDA7038 on a J-pole at the gable, 15 m of CNT-400 | 1.9 dB at 900 MHz, 2.8 dB at 1,800 MHz |
| Server run | One ceiling dome in the hallway, 10 m of CNT-400 | 1.3 dB at 900 MHz, 1.8 dB at 1,800 MHz |
| At the dome | No splitter | Up to 18.7 dBm at 900 MHz, 18.2 dBm at 1,800 MHz |
Both runs are inside 3 dB, and the roof and a wall separate the two antennas. This is the pack as it ships.
| Part | Choice | Loss or level |
|---|---|---|
| Unit | G51 "Mini-LPDA + Panel" pack | 27 dBm on n78, 20 dBm on 4G |
| Donor run | LPDA7040 on the roof, 10 m of CNT-400 | 2.7 dB at 3,600 MHz |
| Split | Two-way Wilkinson | Up to 3.6 dB |
| Server runs | Two wall panels, on 10 m and 15 m of CNT-400 | 2.7 dB and 4.1 dB at 3,600 MHz |
| At the panels | Up to 20.7 and 19.3 dBm on n78; 14.6 and 13.6 dBm on an 1,800 MHz channel |
The two legs differ by 1.4 dB, so an equal split is right. Keep the unit near the middle of the building so that neither leg grows.
| Part | Choice | Loss or level |
|---|---|---|
| Unit | G41, unit only | 20 dBm maximum |
| Donor run | LPDA7038 on a mast at the far corner, 35 m of LDF4-50A | 2.4 dB at 900 MHz, 3.5 dB at 1,800 MHz (CNT-400 would lose 4.5 and 6.4 dB) |
| Split | Four-way | Up to 6.9 dB |
| Server runs | Four ceiling domes, 20 m each | CNT-400: 3.7 dB at 1,800 MHz. LDF4-50A: 2.0 dB |
| At each dome | Up to 9.4 dBm on CNT-400, 11.1 dBm on LDF4-50A |
This design depends on the donor signal. If the unit's downlink sits under 3 dBm, Nextivity's rule says not to split four ways: fit two panels, one at each end, and revisit the donor antenna.
| Part | Choice | Loss or level |
|---|---|---|
| Units | Two G41s, one set to each carrier | 20 dBm maximum each |
| Donor runs | Two LPDAs, each aimed at its own tower | As Example 1 for each |
| Combiner | 2x2 hybrid | Up to 3.85 dB |
| Server runs | Two ceiling domes, 10 m of CNT-400 each | 1.8 dB at 1,800 MHz |
| At each dome | Both carriers | Up to 14.3 dBm for each carrier |
Two permissions are needed, one from each carrier.
Before you leave the site:
Nextivity's quick start guide covers two cases, road vehicles and boats, and its first line applies to both: the unit is electronic equipment that must stay dry, cool and ventilated.
Which whip suits which vehicle is in the pack table in our selection guide.
The guide's marine drawing shows the same parts arranged for a cruiser: the donor antenna high on the superstructure, the unit inside with its ground cable and a drip loop in the antenna lead, and the server antenna in the saloon. Nextivity notes that the drawing represents small to medium boats, typically up to 15 m. Two points matter more afloat than on the road. Fibreglass does little to shield one antenna from the other, so separation has to come from distance and height. And the power feed should come from the vessel's 12 V supply through an accessory socket, with a converter on a 24 V system. The Store's ROAM R41 pack has a marine version of the CDQ8195 for this job.
| Light | Meaning |
|---|---|
| Solid orange | Powered on |
| Slow blinking green | Scanning for the network |
| Solid green | Working and providing coverage |
| Solid red | Hardware error: disconnect and reconnect |
| Red, one flash | No signal from the network |
| Red, two flashes | Donor signal too strong |
| Red, three flashes | Cabin antenna too close to the donor antenna |
| Red, four flashes | Disabled by the carrier |
| Red, five flashes | Location lock pending |
| Red, six flashes | Registration pending |
| Red, seven flashes | Self-test failed |
| Red, eight flashes | Overheating |
In a building with timber-framed or plasterboard walls, about 25 to 35 m, so that two areas of roughly 20 m radius overlap. With brick or concrete internal walls, plan one antenna per walled zone. In an open shed, 60 to 100 m. Confirm with a walk test, and remember that each split takes power from both antennas.
No. They should lose about the same, within roughly 3 dB, which at 1,800 MHz is a difference of about 16 m of CNT-400. When the lengths differ by more, move the splitter, use lower-loss cable on the long leg, or use a directional coupler so that the far antenna receives the larger share.
Yes, through a 2x2 hybrid combiner, which is how a site gets two carriers from one set of server antennas. Each carrier arrives at each antenna about 3 dB down. The combiner must be a high-isolation type; a reactive power divider is not suitable for joining two units.
Nextivity's G51 guide asks for more than 20 dB of isolation between splitter ports, which a Wilkinson two-way provides. A two-way split costs each antenna up to 3.6 dB and a four-way up to 6.9 dB, and the guide asks for a downlink above 0 dBm before a two-way split and above 3 dBm before a four-way.
Go by the length of the run. The rule of thumb is low-loss cable in the RG58 size, such as 9006, under about 10 m, CNT-400 from 10 to 25 m, and 1/2 inch LDF4-50A beyond 25 m. For a G51 on band n78, move up a cable size earlier: at 3,600 MHz a 15 m run loses 4.1 dB in CNT-400 and 2.2 dB in LDF4-50A.
Yes to both. A newly installed unit is registered in the Nextivity WAVE App before it goes into service. Nextivity then releases software updates from time to time, and some are essential, so apply them when they are offered.
Two or three floors: one GO split between the floors, or one per floor. More than that: a QUATRA system, which puts a powered Coverage Unit on each floor, fed over category cable.
Yes. Nextivity's quick start guide has a marine layout for small to medium boats: donor antenna high on the superstructure, the unit inside and dry, and the server antenna in the saloon, powered from the 12 V supply.
Send us the carrier or carriers, a sketch or floor plan with rough dimensions, the wall construction, and the signal your phone shows at the roof and inside. We will come back with the unit, the antennas, the cable for each run, and the splitter or combiner, and with the loss budget behind the choice. The parts named in this guide are in the Cel-Fi collection and in the antenna, cable and connector ranges on the Store.
The manufacturer pages and datasheets linked in this article were read on 1, 8 and 14 November 2026. Specifications change, so check the current datasheet before you order.