Coaxial Cables

Selecting an Andrew (CommScope) coaxial cable for your application

31 min read

Four kinds of coaxial cable: 1/2 inch feeder, 7/8 inch feeder, superflexible jumper and braided cable

How to choose Andrew (CommScope) HELIAX, CNT and RADIAX coaxial cable: loss tables, power, fire ratings, connectors, tools and which cable suits which job.

The short answer: Work out the loss you can afford at your highest frequency, then pick the smallest Andrew cable that meets it over your run. In practice that is CNT-400 for short runs to a router or repeater, 1/2 inch LDF4-50A when the run or the frequency makes CNT-400 too lossy, 7/8 inch AVA5-50 for tower feeders, and 1-5/8 inch AVA7-50 for long feeders below 2.7 GHz. Use superflexible FSJ cable for jumpers and tight bends, a fire-retardant RK jacket inside buildings and tunnels, and RADIAX radiating cable where the cable itself has to be the antenna. Then match the connector, the preparation tool and the weatherproofing to that exact cable, because a HELIAX connector fits one cable family only. The tables below give Andrew's published figures for the cables in its current range.

Andrew, CommScope and Amphenol: one range, three names

HELIAX, CNT and RADIAX are Andrew products. Andrew Corporation became part of CommScope in 2007, which is why a generation of installers knows these cables as CommScope. On 3 February 2025 Amphenol completed its purchase of CommScope's outdoor wireless and distributed antenna system businesses, and the business now trades as ANDREW, an Amphenol company.

The part numbers on Andrew's coaxial cable pages are the ones CommScope used: LDF4-50A is still LDF4-50A. Cartons and listings may say CommScope or Andrew depending on when the stock was made, and it is the same cable. In this guide "Andrew" means the maker.

The Andrew coaxial range today

Andrew's site lists 63 coaxial cables in 17 series (read on 14 November 2026). They fall into six families.

Family Series and nominal size Construction Where it is used
HELIAX low density foam (LDF) LDF1-50 (1/4 in), LDF2-50 (3/8 in), LDF4-50A (1/2 in) Corrugated copper outer, copper-clad aluminium inner, foam PE dielectric Feeders and long jumpers. Andrew describes LDF4-50A as its general-purpose outdoor cable
HELIAX Virtual Air (AVA) AVA5-50 and AVA5-50FX (7/8 in), AVA6-50 (1-1/4 in), AVA7-50 (1-5/8 in) Corrugated copper outer, copper tube inner, foam PE dielectric Tower and rooftop feeders, where every tenth of a dB counts
HELIAX aluminium AL5-50 (7/8 in) Corrugated aluminium outer, copper tube inner A lighter 7/8 inch feeder
HELIAX superflexible (FSJ) FSJ1-50A (1/4 in), FSJ2-50 (3/8 in), FSJ4-50B (1/2 in), LSF2-50 (3/8 in, sold in jumpers only) Corrugated copper outer made for a tight bend radius Jumpers, equipment rooms, any run with tight bends
HELIAX special purpose PTS1-50 (1/4 in, plenum rated, high temperature), heat-treated and phase-stabilised versions of the LDF and FSJ cables (the 35422 part numbers), TS041-50 (4.1 mm) As the parent cable, with a different dielectric, jacket or treatment Plenum air spaces and phase-critical systems
CNT braided CNT-300 (0.300 in), CNT-400 (0.400 in) Tinned copper braid over aluminium tape, copper-clad aluminium inner Short, flexible runs to routers, repeaters and antennas

Three things about the part numbers help when you read a quote:

  • The digit is the size. 1 is 1/4 inch, 2 is 3/8 inch, 4 is 1/2 inch, 5 is 7/8 inch, 6 is 1-1/4 inch and 7 is 1-5/8 inch. All of them are 50 ohm, which is the "-50".
  • RK is the fire-retardant jacket. LDF4RK-50A is LDF4-50A in a black, non-halogenated, fire-retardant polyolefin jacket. The same RK versions exist across the LDF, AVA, AL5 and FSJ series. On the braided cables the ending is -FR.
  • A P after the size is a "premium" cable. These carry endings such as -42, -43B, -C or -CBAND. We read the C-band version of LDF4: it has the same dimensions and loss as LDF4-50A, with return loss tested in more bands.

Not everything in service is in the current list. Sites built before the AVA cables often carry LDF5-50A (7/8 inch) and LDF7-50A (1-5/8 inch), and we still supply 5/8 inch LDF4.5RK-50. None of those three series appears in Andrew's list today, where AVA5-50 and AVA7-50 hold the 7/8 and 1-5/8 inch places. The coaxial category we read also holds no air-dielectric cable and no RADIAX radiating cable. We stock RADIAX and cover it under in-building work below.

What the datasheet numbers decide

Operating band, size and weight

A coaxial cable has a top frequency, and the bigger the cable the lower that limit sits. This is the first check, because a cable that is not rated for your band is the wrong cable whatever its loss.

Cable Size Operating band Velocity Peak power Minimum bend radius, single / repeated Weight Diameter over jacket
LDF1-50 1/4 in 1 to 15,800 MHz 86% 12.1 kW 38 / 76 mm 0.09 kg/m 8.8 mm
LDF2-50 3/8 in 1 to 13,000 MHz 85% 15.6 kW 41 / 95 mm 0.12 kg/m 11.2 mm
LDF4-50A 1/2 in 1 to 8,800 MHz 88% 40 kW 51 / 127 mm 0.22 kg/m 15.9 mm
AVA5-50 7/8 in 1 to 5,000 MHz 91% 91 kW 127 / 254 mm 0.45 kg/m 28.0 mm
AL5-50 7/8 in 1 to 5,200 MHz 88% 91 kW 155 / 280 mm 0.385 kg/m 28.0 mm
AVA6-50 1-1/4 in 1 to 4,000 MHz 92% 180 kW 152 / 203 mm 0.68 kg/m 39.6 mm
AVA7-50 1-5/8 in 1 to 2,700 MHz 92% 302 kW 203 / 381 mm 1.07 kg/m 51.1 mm
FSJ1-50A 1/4 in 1 to 18,000 MHz 82% 6.4 kW 25 / 25 mm 0.07 kg/m 7.4 mm
FSJ2-50 3/8 in 1 to 13,400 MHz 83% 13.2 kW 25 / 25 mm 0.12 kg/m 10.5 mm
FSJ4-50B 1/2 in 1 to 10,200 MHz 81% 22.5 kW 32 / 32 mm 0.21 kg/m 13.5 mm
CNT-300 0.300 in 30 to 6,000 MHz 83% 10 kW 22 mm 0.06 kg/m 7.6 mm
CNT-400 0.400 in 30 to 6,000 MHz 85% 16 kW 25 mm 0.10 kg/m 10.3 mm

The line to notice is AVA7-50. It is the lowest-loss cable in the range and it stops at 2,700 MHz, so it cannot carry 3.5 GHz 5G. AVA6-50 reaches 4,000 MHz and AVA5-50 reaches 5,000 MHz.

Impedance

Every cable in the range is 50 ohm, and the HELIAX pages give the tolerance as plus or minus 1 ohm. Radios, antennas, repeaters and test gear for mobile, two-way and microwave work are 50 ohm. Television distribution cable is 75 ohm and is a different product: the two must not be mixed in one run.

Attenuation: the number that usually decides the cable

Loss rises with frequency and falls with cable size. These are Andrew's figures in dB per 100 m, which Andrew describes as typical and guaranteed within 5%, measured at 20 °C.

Cable 150 MHz 450 MHz 894 MHz 1,800 MHz 2,700 MHz 3,600 MHz 6,000 MHz
AVA7-50 (1-5/8 in) 0.80 1.44 2.11 3.16 4.02 not rated not rated
AVA6-50 (1-1/4 in) 1.02 1.83 2.67 3.96 5.02 5.96 not rated
AVA5-50 (7/8 in) 1.43 2.55 3.69 5.44 6.85 8.08 not rated
AL5-50 (7/8 in) 1.67 2.97 4.29 6.30 7.92 9.33 not rated
LDF4-50A (1/2 in) 2.67 4.75 6.86 10.06 12.63 14.88 20.06
FSJ4-50B (1/2 in) 4.21 7.59 11.10 16.57 21.06 25.06 34.43
LDF2-50 (3/8 in) 4.22 7.51 10.87 15.99 20.12 23.75 32.12
FSJ2-50 (3/8 in) 4.86 8.67 12.54 18.47 23.25 27.46 37.16
CNT-400 (0.400 in) 4.92 8.86 12.8 at 900 18.4 22.0 at 2,500 28.9 at 4,000 36.42
LDF1-50 (1/4 in) 4.99 8.88 12.83 18.86 23.70 27.96 37.74
FSJ1-50A (1/4 in) 7.25 12.82 18.42 26.86 33.58 39.43 52.75
CNT-300 (0.300 in) not listed 13.1 19.4 at 900 28.2 33.8 at 2,500 44.6 at 4,000 55.8

Three readings of that table are worth keeping:

  • LDF4-50A has roughly half the dB of CNT-400 at every frequency. Every 3 dB is half your power, in both directions.
  • Superflexible costs loss. FSJ4-50B is the same nominal size as LDF4-50A and loses about 60% more dB. That is the price of the 32 mm bend radius, and it is why FSJ is a jumper cable and not a feeder.
  • CNT-400 sits with the 1/4 and 3/8 inch HELIAX cables on loss, at a fraction of the installation effort. For a short run that is a fair trade.

Our coax cable loss comparison sets CNT-400 beside LMR-400, RG-58 and RG-213.

Power: average, peak and voltage

Three different limits appear on the datasheets.

Average power is a heating limit. Andrew rates it at 40 °C ambient with the inner conductor at 100 °C, and it falls as frequency rises.

Cable Average power at 894 MHz Average power at 1,800 MHz Peak power dc test voltage
LDF1-50 0.57 kW 0.39 kW 12.1 kW not read
LDF2-50 0.71 kW 0.48 kW 15.6 kW not read
LDF4-50A 1.11 kW 0.76 kW 40 kW 4,000 V
FSJ4-50B 0.95 kW 0.64 kW 22.5 kW 2,500 V
AVA5-50 2.27 kW 1.54 kW 91 kW 6,000 V
AVA6-50 2.46 kW 1.66 kW 180 kW not read
AVA7-50 3.44 kW 2.30 kW 302 kW 15,000 V
CNT-400 not listed not listed 16 kW 2,500 V

Peak power and dc test voltage are insulation limits. They matter for pulsed systems such as radar and for high-power broadcast, and hardly at all for a 40 W base station.

RF operating voltage belongs to the connector, and the connector is usually the weakest link. Andrew's L4TNM-PSA, the N male for LDF4-50A, is rated at 707 V rms maximum RF operating voltage, 10 kW peak, 2,000 V dc test and 0.6 kW average at 900 MHz. So a 1/2 inch run with N connectors is a 0.6 kW system at 900 MHz, not the 1.11 kW the cable alone could carry. For high power, choose the cable and the connector interface together.

Return loss and VSWR

Return loss says how much of the signal is reflected by the cable itself. Andrew tests each cable in named bands, and the figure only holds in those bands.

Cable Tested bands VSWR / return loss
LDF4-50A 680 to 800, 800 to 960, 1,700 to 2,200 and 2,300 to 2,700 MHz 1.13 / 24.3 dB
AVA5-50 680 to 800, 800 to 960 and 1,700 to 2,200 MHz 1.13 / 24.3 dB
AVA6-50 and AVA7-50 680 to 800, 806 to 960 and 1,700 to 2,170 MHz 1.13 / 24.3 dB
FSJ4-50B 680 to 800, 800 to 960, 1,700 to 2,200 and 2,300 to 2,700 MHz 1.20 / 20.8 dB
LDF1-50 806 to 960 and 1,700 to 2,000 MHz; 4,000 to 6,000 MHz 1.15 / 23.1 dB; 1.43 / 15.0 dB
LDF4P-50A-CBAND As LDF4-50A, plus 3,450 to 4,200, 4,200 to 4,800 and 5,150 to 5,925 MHz 19 dB, 16 dB and 16 dB in the three upper bands

If your system works above 2.7 GHz, the standard LDF4-50A page gives no return loss figure for it. That is what the premium, C-band tested cable is for. The "DOD" in its description is the name of a 5G band, one of the bands the cable is tested in; it is not a defence grade.

The connector has its own figure. The L4TNM-PSA is rated at 38.9 dB to 1,000 MHz, 35 dB to 2,200 MHz, 33 dB to 3,000 MHz, 27 dB to 4,000 MHz and 19 dB to 6,000 MHz.

Shielding and intermodulation

Andrew rates CNT-400 and CNT-300 at 90 dB shielding effectiveness. The HELIAX cable pages give no figure, because the outer conductor is a continuous metal tube, not a braid; the L4TNM-PSA connector is rated at 130 dB.

Passive intermodulation (PIM) matters where several high-power carriers share one cable, as on a mobile base station. The L4TNM-PSA is rated at -116 dBm third-order intermodulation at 910 MHz with two +43 dBm carriers. Andrew's SureFlex jumpers come in standard, Premium (static PIM) and D-CLASS (dynamic PIM) grades. Braided cable is the usual choice for a single radio, a router or a repeater, and corrugated cable with low-PIM connectors is the usual choice for a multi-carrier base station.

Flexibility and handling

Cable Bends it is rated for, minimum / typical Bending moment Tensile strength Flat plate crush
LDF4-50A 15 / 50 3.8 N-m 113 kg 2.0 kg/mm
FSJ4-50B 20 / 50 2.7 N-m 79 kg 2.0 kg/mm
AVA5-50 15 / 30 19 N-m 159 kg 1.3 kg/mm
AVA7-50 15 / 50 47.5 N-m 181 kg 1.6 kg/mm
CNT-400 not listed not listed 73 kg 0.7 kg/mm

Corrugated copper will take a set, and it work-hardens: it is rated for a number of bends, not for flexing every day. The bending moment tells the rigger how hard the cable is to form. AVA7-50 takes more than twelve times the effort of LDF4-50A, and at 1.07 kg per metre a 60 m run weighs 64 kg before the hoisting grip goes on. CNT-400 has a third of the crush strength of the corrugated cables, so it should not be clamped hard or walked on.

Fire performance

The standard black polyethylene jacket is halogen-free and is not fire-retardant. It is an outdoor jacket. Indoors, in risers and in tunnels, the jacket is chosen by the fire rating the site calls for.

Jacket Example Ratings Andrew lists Where it goes
Standard PE LDF4-50A, AVA5-50, FSJ4-50B None: halogen-free, non-fire-retardant Outdoors: towers, rooftops, poles
RK, non-halogenated fire-retardant polyolefin LDF4RK-50A Flame: IEC 60332-1-2, NFPA 130, UL 1666 riser (CATVR/CMR). Smoke: IEC 61034. Acid gas: IEC 60754-1 and -2. Euroclass B2ca-s1a-d1-a1 under EN 50575 Risers, plant rooms, tunnels, rail and in-building systems
Plenum PTS1-50-P NFPA 262 (CMP) and UL 910 (CATVP); foam FEP dielectric, fire-retardant PVC jacket Air-handling ceiling and floor spaces
-FR on braided cable CNT-400-FR, CNT-300A-FR Non-halogenated fire-retardant polyolefin jacket In-building tails and jumpers

Two cautions. The RK jacket narrows the temperature range to -40 to +70 °C, against -55 to +85 °C for the PE cable. And the rating that applies is the one the building's fire engineer, the carrier or the rail authority specifies, so ask for it before ordering.

Environment, moisture and corrosion

The HELIAX PE cables are rated for installation from -40 to +60 °C, operation from -55 to +85 °C and storage from -70 to +85 °C. CNT-400 is rated from -40 to +85 °C for installation and operation.

Water does not enter a sound jacket. It enters at the connector, so that is where Andrew publishes its environmental tests. These are the figures for the L4TNM-PSA:

Test Method and condition
Immersion 1 m depth, unmated, IEC 60529, IP68
Water jetting Unmated, IEC 60529, IP66
Moisture resistance MIL-STD-202F, Method 106F
Thermal shock MIL-STD-202F, Method 107G, Test Condition A-1, low temperature -55 °C
Vibration IEC 60068-2-6
Mechanical shock MIL-STD-202, Method 213, Test Condition I
Corrosion MIL-STD-1344A, Method 1001.1, Test Condition A
Interface durability 500 matings, IEC 61169-16
Plating Silver inner contact, trimetal outer contact

Those tests describe a connector fitted to the right cable with the right tool. A connector fitted to a badly prepared cable passes none of them, which is why the preparation tools further down matter as much as the connector. Outdoors, every joint is then wrapped or cold-shrunk as well. AL5-50 has an aluminium outer conductor, and aluminium and copper behave differently in salt air, so its connectors and sealing should follow Andrew's instructions exactly.

Compliance

Andrew's cable pages list RoHS and UK RoHS compliance, China RoHS below the maximum concentration value, REACH SVHC compliance against the current list, EN 50575 with a Declaration of Performance available, and manufacture under an ISO 9001:2015 quality system. Connectors differ slightly: the L4TNM-PSA is listed as RoHS "compliant/exempted". If a tender asks for certificates, ask for them by part number.

Which cable for which job

Application Andrew cable Why
Mobile tower or rooftop feeder AVA5-50 for most runs, AVA6-50 or AVA7-50 for long ones, with FSJ4-50B or SureFlex jumpers at each end Lowest loss and highest power. AVA7-50 only below 2.7 GHz
Small cell, short feeder, rooftop link LDF4-50A Half the loss of braided cable, light enough to run by hand
VHF and UHF two-way radio, repeater sites LDF4-50A; AVA5-50 on tall masts At 150 MHz LDF4-50A loses 2.67 dB per 100 m, so a 45 m run costs 1.2 dB
Cellular repeater (Cel-Fi GO and similar), router and modem antennas CNT-400 for short runs; LDF4-50A when the loss budget runs out Flexible, quick to terminate, 90 dB shielding
DAS and in-building coverage LDF4RK-50A and AVA5RK-50 in risers, FSJ4RK-50B for tails, CNT-400-FR for short drops The fire-retardant jacket is the deciding feature
Tunnels, car parks, lift shafts, long corridors RADIAX radiating cable: RCT4 (1/2 in, 50 to 3,800 MHz) or RCT5 (7/8 in, 50 to 2,800 MHz) The cable radiates along its length, so coverage follows the cable
Equipment rooms, combiners, test benches FSJ1-50A, FSJ2-50, LDF1-50, LDF2-50 Small, tight bends, rated to 13 GHz and above
Radar, phased arrays and other phase-critical systems Phase-stabilised LDF4-50A and FSJ4-50B, heat-treated LDF1, LDF2, FSJ1 and FSJ2 (the 35422 part numbers) Electrical length that holds with temperature
High-temperature or plenum runs PTS1-50 Foam FEP dielectric, rated to 20 GHz
Military or government communications station (fixed) AVA5-50 as the standard feeder, AVA7-50 for the longest and highest-power runs, RK versions indoors Long runs and kilowatt-class transmitters at VHF and UHF

Telecom towers

A tower feeder is chosen on loss, then checked for weight and wind load. The 7/8 inch AVA5-50 is the usual feeder; AVA5-50FX has the same loss at 0.41 kg per metre against 0.45. Long runs at 700 to 2,100 MHz justify AVA6-50 or AVA7-50. The feeder never connects straight to the antenna or the radio: a short superflexible jumper at each end takes the bends and the movement.

DAS, in-building and tunnels

Indoors the order of the questions changes: fire rating first, then loss. The RK cables carry riser and low-smoke ratings and a Euroclass under EN 50575, and the same connectors fit them as fit the PE cable of the same size. Where a corridor, tunnel or car park is too long for point antennas, radiating cable replaces them.

Cellular repeaters and routers

A repeater system lives or dies on the donor cable, because loss there cannot be bought back. CNT-400 is right for most donor and server runs. When the run is long, or the band is 3.5 GHz, the table above shows the saving from LDF4-50A. Our antenna guide covers the antennas at each end.

Defence: a military communications station

A fixed defence site, such as a communications station, an air base radio site or a radar head, is built like any other fixed radio site, and the same selection method applies. What changes is the emphasis. Runs from the equipment building to the antenna field are long, transmitters are often more powerful, and some systems care about phase as much as loss. Example 7 in the next section works one through. Three parts of the range matter:

  • Low-loss feeders for long, high-power runs. AVA5-50 and AVA7-50 carry several kilowatts at VHF and UHF.
  • Phase-stabilised and heat-treated cables. A phased array steers its beam by the phase of the signal at each element, so the feeders must keep the same electrical length as the temperature moves. Andrew lists phase-stabilised LDF4-50A and FSJ4-50B and heat-treated LDF1-50, LDF2-50, FSJ1-50A and FSJ2-50. The pages give no phase figure, so ask for it against your temperature range.
  • High-temperature superflexible cable. An Andrew bulletin for its 1/4 inch high-temperature superflexible HELIAX listed electronic warfare, military phased array radar, airborne and shipboard radar and missile systems among its uses. The 1/4 inch high-temperature cable in today's list is PTS1-50, rated from 1 to 20,000 MHz.

What the range is not: it is not a MIL-DTL-17 catalogue. Deployable and vehicle-mounted military radios, and any cable that must meet a military specification by name, need a cable qualified to that specification.

Worked examples: find the job closest to yours

Each example below takes a common job, puts the candidate cables side by side with Andrew's loss figures, and ends with what we would fit and what to order. The percentage beside a loss is the share of the power that reaches the far end of the cable. Connectors and jumpers add a little more loss on top.

Our working rule is to keep a cable run under 3 dB where the site allows it. At 3 dB half the power is gone, in both directions.

Your job Worked example
Cel-Fi GO or other repeater with a roof antenna View example
4G or 5G router or modem with an outdoor antenna View example
Mobile tower or rooftop base station feeder View example
3.5 GHz 5G small cell or fixed wireless View example
VHF or UHF two-way radio repeater View example
In-building coverage (DAS) with risers View example
Military or government communications station View example

Example 1: a Cel-Fi GO repeater with a roof antenna

The job. A donor antenna on the roof feeds a repeater inside, and a second cable runs from the repeater to the indoor antenna. Loss in the donor cable cannot be bought back: every dB lost before the repeater is a dB of weaker signal for it to work with.

Donor run CNT-400 at 900 MHz LDF4-50A at 900 MHz CNT-400 at 1,800 MHz LDF4-50A at 1,800 MHz Our pick
10 m 1.3 dB 0.7 dB 1.8 dB 1.0 dB CNT-400
20 m 2.6 dB 1.4 dB 3.7 dB 2.0 dB CNT-400; LDF4-50A if the donor signal is weak
30 m 3.8 dB 2.1 dB 5.5 dB 3.0 dB LDF4-50A
50 m 6.4 dB 3.4 dB 9.2 dB 5.0 dB LDF4-50A

Recommendation. Up to about 15 m, fit CNT-400: the loss stays under 3 dB at 900 and 1,800 MHz and the cable is easy to route. From 15 to 25 m the choice depends on the donor signal, so measure it first: a strong signal tolerates CNT-400, a marginal one deserves LDF4-50A. Beyond 25 m fit LDF4-50A. The indoor (server) run is usually short, and CNT-400 suits it.

What to order. CNT-400 by the metre with Pulse N-201 connectors, or a made-up Pulse CNT-400 lead. For the longer run, LDF4-50A with two L4TNM-PSA connectors, the MCPT-L4 tool and a 221213 weatherproofing kit for the roof end.

Example 2: a 4G or 5G router with an outdoor antenna

The job. A router or modem indoors, a MIMO antenna outside, and one cable for each antenna port: two runs for a 2x2 router, four for a 4x4. The runs should be the same cable and the same length. On 5G the 3.5 GHz band sets the limit, because loss is highest there.

Each run CNT-400 at 900 MHz CNT-400 at 1,800 MHz CNT-400 at 3,600 MHz LDF4-50A at 3,600 MHz Our pick
5 m 0.6 dB 0.9 dB 1.4 dB 0.7 dB CNT-400
10 m 1.3 dB 1.8 dB 2.7 dB 1.5 dB CNT-400
15 m 1.9 dB 2.8 dB 4.1 dB 2.2 dB CNT-400 for 4G; LDF4-50A for 3.5 GHz
20 m 2.6 dB 3.7 dB 5.4 dB 3.0 dB CNT-400 for 4G; LDF4-50A for 3.5 GHz
30 m 3.8 dB 5.5 dB 8.1 dB 4.5 dB LDF4-50A, or move the router

Recommendation. Keep 3.5 GHz runs in CNT-400 to about 10 m, and 4G-only runs to about 15 m. Past that, either step up to LDF4-50A or shorten the coax: a router mounted near the antenna, with Ethernet run back to the office, loses nothing in the Ethernet. Many outdoor antennas arrive with their own fitted leads, so add the lead's loss to the extension before deciding.

What to order. CNT-400 by the metre or on a 100 m reel, Pulse N-201 and N-200 connectors, the JST-400A stripper and the Pulse RCT-214 crimp tool. Our antenna guide covers the antenna and the router ports.

Example 3: a 60 m mobile tower or rooftop feeder

The job. A base station radio at ground level and a panel antenna 60 m of cable away, on bands from 700 to 2,600 MHz. The feeder is chosen on loss, then checked against the weight and wind load the structure can carry.

Cable 60 m at 894 MHz 60 m at 1,800 MHz 60 m at 2,700 MHz Weight of the run Verdict
LDF4-50A, 1/2 in 4.1 dB (39%) 6.0 dB (25%) 7.6 dB (17%) 13 kg Too lossy for a 60 m main feeder
AVA5-50, 7/8 in 2.2 dB (60%) 3.3 dB (47%) 4.1 dB (39%) 27 kg The usual choice
AVA6-50, 1-1/4 in 1.6 dB (69%) 2.4 dB (58%) 3.0 dB (50%) 41 kg When 2.2 dB is too much
AVA7-50, 1-5/8 in 1.3 dB (75%) 1.9 dB (65%) 2.4 dB (57%) 64 kg Lowest loss; nothing above 2.7 GHz

Recommendation. Fit AVA5-50. It delivers 60% of the power at 894 MHz against 39% for LDF4-50A, at 27 kg for the run. Move up to AVA6-50 or AVA7-50 when the run is longer, when low-band coverage is the whole point of the site, or when the link budget is tight, and check the structure first: the AVA7-50 run weighs 64 kg. A 2 m FSJ4-50B jumper at each end adds 0.4 dB at 894 MHz and 0.7 dB at 1,800 MHz.

What to order. AVA5-50 by the metre with AL5NM-PSA or 78EZNM N connectors or A5HM-D 4.3-10 connectors, the CPT-78U or 78-HPT tool to suit the connector, SnapStak hangers, an earthing kit for each bonding point and a weatherproofing kit for each outdoor connector. FSJ4-50B or made-up SureFlex jumpers finish each end.

The job. A radio on the 3.5 GHz band with 30 m of feeder to the antenna. Two things change at this frequency: loss is high in every cable, and the biggest cable in the range is not rated for the band at all.

Cable 30 m at 3,600 MHz Power delivered Verdict
CNT-400 8.1 dB 15% No: most of the power is lost
LDF4-50A, 1/2 in 4.5 dB 36% Acceptable for a low-power radio
AVA5-50, 7/8 in 2.4 dB 57% The usual choice
AVA6-50, 1-1/4 in 1.8 dB 66% Best loss; rated to 4,000 MHz
AVA7-50, 1-5/8 in Not rated Not rated No: rated to 2,700 MHz only

The CNT-400 figure is interpolated between Andrew's 3,000 and 4,000 MHz values.

Recommendation. Fit AVA5-50, and ask for the version with return loss tested in the band (the premium, C-band cable), because the standard pages quote no return loss above 2,700 MHz. Better still, shorten the feeder: a radio mounted beside the antenna needs only a 2 m FSJ4-50B jumper, which loses 0.5 dB.

What to order. AVA5-50 or AVA6-50 by the metre with 4.3-10 connectors (A5HM-D for AVA5-50), the matching preparation tool, hangers, earthing and weatherproofing as in Example 3.

Example 5: a VHF or UHF two-way radio repeater, 45 m

The job. A land mobile repeater in a hut with its antenna 45 m of cable up a mast, at 150 MHz or 450 MHz. Loss is low at these frequencies, so the case for a big cable is weaker and the case for a cable that lasts on an exposed mast is stronger.

Cable 45 m at 150 MHz 45 m at 450 MHz Verdict
CNT-400 2.2 dB (60%) 4.0 dB (40%) Fine for a short, sheltered run
LDF4-50A, 1/2 in 1.2 dB (76%) 2.1 dB (61%) The usual choice
AVA5-50, 7/8 in 0.6 dB (86%) 1.1 dB (77%) For tall masts and shared sites

Recommendation. Fit LDF4-50A. It keeps a UHF run to about 2 dB, its solid copper outer conductor does not let water track along a braid, and it takes the low-PIM connectors a shared site needs. Move to AVA5-50 for UHF on runs past about 60 m, or where the repeater shares its antenna through a combiner and every dB is already spoken for.

What to order. LDF4-50A, L4TNM-PSA N male or L4TDM-PSA 7-16 DIN male connectors, the MCPT-L4 tool, SnapStak hangers, a 241088-1 earthing kit for each bonding point and a 221213 weatherproofing kit.

Example 6: in-building coverage with an 80 m riser

The job. A distributed antenna system in a multi-storey building: a backbone up the riser, a branch along each floor and short tails to the ceiling antennas. Indoors the first question is the fire rating, and the second is loss.

Cable 80 m riser at 1,800 MHz 80 m riser at 3,600 MHz Weight Euroclass Use it for
LDF4RK-50A, 1/2 in 8.0 dB 11.9 dB 0.25 kg/m B2ca-s1a-d1-a1 Floor runs and short risers
AVA5RK-50, 7/8 in 4.4 dB 6.5 dB 0.53 kg/m B2ca-s1a-d2-a1 The riser backbone

The RK cables have the same loss as the PE cables of the same size; only the jacket and the temperature range differ.

Recommendation. Run AVA5RK-50 up the riser and LDF4RK-50A along the floors, with FSJ4RK-50B or CNT-400-FR for the last metres to each antenna. Where a corridor, car park or lift lobby is long and narrow, replace the row of antennas with RADIAX radiating cable. Confirm the required fire rating with the building's fire engineer or the carrier before ordering: the rating, not the loss, is what gets a DAS rejected at handover.

What to order. AVA5RK-50 and LDF4RK-50A by the metre, FSJ4RK-50B for tails, CNT-400-FR for short drops, and RCT4 or RCT5 radiating cable. The connectors and tools are the same as for the PE cable of the same size.

Example 7: a military or government communications station

The job. A fixed station with VHF and UHF radios in an equipment building and an antenna field 100 m of cable away. Transmitters run from tens of watts to a kilowatt or more, several services share the site, and some antennas are arrays that depend on phase.

Cable 100 m at 150 MHz 100 m at 450 MHz Average power rating at 150 / 450 MHz Use it for
LDF4-50A, 1/2 in 2.7 dB (54%) 4.7 dB (34%) 2.85 kW / 1.61 kW Short runs and receive-only antennas
AVA5-50, 7/8 in 1.4 dB (72%) 2.6 dB (56%) 5.86 kW / 3.29 kW The general-purpose feeder
AVA7-50, 1-5/8 in 0.8 dB (83%) 1.4 dB (72%) 9.09 kW / 5.04 kW Longest runs and highest power

Recommendation. Fit AVA5-50 as the standard feeder: it delivers 72% of the power at 150 MHz and 56% at 450 MHz over 100 m, and is rated above 3 kW average at 450 MHz. Use AVA7-50 for the longest runs and the highest-power transmitters, remembering that the connector, not the cable, usually sets the power limit. Inside buildings and cable tunnels, use the RK fire-retardant versions. For direction-finding and phased arrays, ask for the phase-stabilised cables and for a phase figure against your temperature range. If the contract names a military cable specification, that specification governs and this range may not qualify.

What to order. AVA5-50 or AVA7-50 by the metre or on a drum, AL5NM-PSA or AL7NM-PSA connectors, the CPT-78U or A7-EZPT tool, a hoisting grip for the 1-5/8 inch cable, and earthing and weatherproofing at every outdoor joint.

Where Andrew cable has been used

These are projects where the supplier or the trade press named the cable.

Use Project What was installed
Mobile network build China Telecom CDMA network, 2008 Base station antennas with HELIAX cable and accessories, for part of a build of about 15,000 sites
Mobile network build Powertel, south-eastern United States, 1999 HELIAX cable with its connectors, SureFlex jumpers and earthing kits, and EASIAX preparation tools to speed installation across 12 states
Mobile network build Tata Teleservices, India HELIAX FXL smooth-wall feeder cable at new base station sites
Television broadcast Two Tulsa TV stations, 2018 HELIAX flexible transmission line between the transmitters and new antennas on a city building
Rail Kowloon-Canton Railway West Rail, Hong Kong RADIAX radiating cable with HELIAX coaxial cable and connectors, in nine stations and along part of the track
Rail tunnel Gotthard Base Tunnel, Switzerland RADIAX radiating cable with a fibre-fed distributed antenna system, through the rail tubes and 153 km of access and service tunnels
Utility tunnel Ausgrid cable tunnel, Sydney RADIAX fixed to the ceiling of a 4 m diameter tunnel during construction, for two-way radio between tunnel and surface crews

The Powertel order is the pattern to copy on any job: the cable, its connectors, the jumpers, the earthing kits and the preparation tools were bought as one system.

Connectors: Andrew and Pulse

A HELIAX connector is made for one cable. The first characters name it: L4 fits LDF4, F4 fits FSJ4, and a 7/8 inch connector for AVA5 will not go on LDF4.

Cable Andrew connectors we stock Pulse alternative
CNT-400 400BPNM-C N male, 400BPNF-C N female, 400APNM-CS8 N male, 400PSM-CR SMA male, with TNC, BNC and 7-16 DIN versions Pulse N-201 N male and Pulse N-200 N female (captive pin, crimp), N-205 N male (solder or crimp), D43-111 4.3-10 male
LDF1-50 L1TNM-PL N male
LDF2-50 L2TNM-PL N male
LDF4-50A and LDF4RK-50A L4TNM-PSA N male, L4TNF-PSA N female, L4TDM-PSA 7-16 DIN male, L4HM-D 4.3-10 male
FSJ1-50A F1TNM-HC N male
FSJ2-50 F2TNM-PL N male
FSJ4-50B F4PNMV2-HC N male, F4HM-D 4.3-10 male
AVA5-50 and AVA5-50FX AL5NM-PSA N male, 78EZNM EZfit N male, A5HM-D 4.3-10 male
AVA6-50 114EZNM EZfit N male, A6HM-S 4.3-10 male
AVA7-50 AL7NM-PSA N male, A7HM-S 4.3-10 male

The Pulse N-201 and N-200 are the connectors most CNT-400 leads leave our bench with. They crimp with the Pulse RCT-214 tool, and we also sell made-up Pulse CNT-400 leads in 10, 15 and 20 m lengths. Our guides to which connector goes with which cable and to compression, crimp and solder connectors go further.

On interface: N is the general-purpose choice, 7-16 DIN is the older high-power base station interface, and 4.3-10 is the current low-PIM interface on mobile equipment.

Cable preparation tools

Corrugated cable is cut, stripped and flared to exact lengths before the connector goes on. The tool is specific to the cable and to the connector series.

Cable Tool Type Prepares the cable for
LDF4-50A MCPT-L4 Manual PSA and F-Class connectors
LDF4-50A CPT-L4ARC1 Automated, drill driven PSA, PS, C and BHC connectors
LDF4-50A CPT-L4-D Automated D-Class connectors
LDF4-50A L4310-GT Manual S-Class, HM-F and HF-F connectors
FSJ1-50A CPT-F1-D Automated D-Class connectors
FSJ2-50 CPT-F2-D Automated D-Class connectors
FSJ4-50B CPT-F4-D, CPT-F4B Automated D-Class connectors; FSJ4-50B generally
AVA5-50 CPT-78U Automated PSA connectors
AVA5-50 78-HPT Manual EZfit, S-Class and F-Class connectors
AVA5-50 and AVA5-50FX A5FX-EZPT Automated EZfit connectors
AVA6-50 CPT-114U, A6-EZPT Automated PSA connectors; EZfit connectors
AVA7-50 A7-EZPT Automated EZfit connectors
CNT-400 JST-400A jacket stripper, Pulse RCT-214 crimp tool Manual Crimp connectors

Buy the tool with the first connectors. A hacksaw and a knife will get a connector onto LDF4-50A, and the return loss and the water seal will both show it.

Weatherproofing, earthing and support

  • Weatherproofing. The Andrew 221213 kit is the butyl and PVC tape kit for connectors and splices. Andrew also lists cold shrink kits, 245173 and 245174. Every outdoor connector gets one or the other.
  • Earthing. The cable's outer conductor is bonded to the structure with an earthing (grounding) kit, such as the 241088-1 for 1/2 inch cable. Where the kits go is part of the site's earthing and lightning protection design, usually at the top of the run, at the bottom and at the building entry.
  • Support. SnapStak hangers for 1/2 inch and 7/8 inch cable stack several runs on one fixing. Click-on hangers, KwikClamp hangers and butterfly hangers cover other structures, and a hoisting grip carries the weight of a 1-5/8 inch cable up the tower so the connector does not.

How we supply it: cut lengths, reels and drums

  • Cut to length. LDF4-50A, AVA5-50, AVA5-50FX, AVA6-50, AVA7-50 and CNT-400 are sold by the metre, cut to the length you order.
  • Ready-made reels. CNT-400 comes on 50 m and 100 m reels from the maker, and CNT-400-FR on a 150 m roll.
  • Drums. Full drums are mostly 500 m: CNT-400 and CNT-400-FR are listed that way, and Andrew lists LDF4RK-50A on a 500 m reel. For a project, a drum avoids joints and offcuts.
  • Made-up leads and jumpers. Pulse CNT-400 leads and Andrew SureFlex jumpers in 4.3-10 and 7-16 DIN arrive terminated and tested, which is the right answer when nobody on site has the preparation tool.

The full range is in our coaxial cables, CommScope, Pulse and RF connectors collections.

Frequently asked questions

Is Andrew cable the same as CommScope cable?

Yes. Andrew was part of CommScope from 2007, and since February 2025 it has been ANDREW, an Amphenol company. HELIAX, CNT and RADIAX part numbers did not change.

What is the difference between LDF4-50A and FSJ4-50B?

Both are 1/2 inch, 50 ohm HELIAX. LDF4-50A is the feeder: 6.86 dB per 100 m at 894 MHz and a 127 mm repeated bend radius. FSJ4-50B is the jumper: 11.10 dB per 100 m and a 32 mm bend radius. They take different connectors.

Can AVA7-50 carry 5G at 3.5 GHz?

No. Andrew rates AVA7-50 from 1 to 2,700 MHz. Use AVA6-50 (to 4,000 MHz) or AVA5-50 (to 5,000 MHz).

How long can a CNT-400 run be?

As long as the loss budget allows. At 900 MHz CNT-400 loses 12.8 dB per 100 m, so 3 dB, half the power, is gone in about 23 m. At 1,800 MHz that point comes at about 16 m. Beyond it, move to LDF4-50A.

Do I need fire-retardant cable indoors?

In risers, plant rooms, tunnels and rail environments, almost always. The standard PE jacket is not fire-retardant. The RK cables carry the flame, smoke and acid gas ratings, and the site's fire specification says which rating is required.

Do Pulse connectors fit Andrew CNT-400?

Yes. The Pulse N-201 and N-200 are made for CNT-400, and several Pulse connectors list CNT-400 and LMR-400 together.

Does HELIAX need a special tool?

It needs the preparation tool made for that cable and connector series. The connector's return loss and its IP68 seal both depend on the cut.

Talk to us about your run

Send us the frequency, the run length, the power and where the cable goes (tower, riser, tunnel, cabinet), and we will come back with the cable, the connectors, the tool and the weatherproofing as one list, cut to length or on a drum.