How to choose Andrew (CommScope) HELIAX, CNT and RADIAX coaxial cable: loss tables, power, fire ratings, connectors, tools and which cable suits which job.
The short answer: Work out the loss you can afford at your highest frequency, then pick the smallest Andrew cable that meets it over your run. In practice that is CNT-400 for short runs to a router or repeater, 1/2 inch LDF4-50A when the run or the frequency makes CNT-400 too lossy, 7/8 inch AVA5-50 for tower feeders, and 1-5/8 inch AVA7-50 for long feeders below 2.7 GHz. Use superflexible FSJ cable for jumpers and tight bends, a fire-retardant RK jacket inside buildings and tunnels, and RADIAX radiating cable where the cable itself has to be the antenna. Then match the connector, the preparation tool and the weatherproofing to that exact cable, because a HELIAX connector fits one cable family only. The tables below give Andrew's published figures for the cables in its current range.
HELIAX, CNT and RADIAX are Andrew products. Andrew Corporation became part of CommScope in 2007, which is why a generation of installers knows these cables as CommScope. On 3 February 2025 Amphenol completed its purchase of CommScope's outdoor wireless and distributed antenna system businesses, and the business now trades as ANDREW, an Amphenol company.
The part numbers on Andrew's coaxial cable pages are the ones CommScope used: LDF4-50A is still LDF4-50A. Cartons and listings may say CommScope or Andrew depending on when the stock was made, and it is the same cable. In this guide "Andrew" means the maker.
Andrew's site lists 63 coaxial cables in 17 series (read on 14 November 2026). They fall into six families.
| Family | Series and nominal size | Construction | Where it is used |
|---|---|---|---|
| HELIAX low density foam (LDF) | LDF1-50 (1/4 in), LDF2-50 (3/8 in), LDF4-50A (1/2 in) | Corrugated copper outer, copper-clad aluminium inner, foam PE dielectric | Feeders and long jumpers. Andrew describes LDF4-50A as its general-purpose outdoor cable |
| HELIAX Virtual Air (AVA) | AVA5-50 and AVA5-50FX (7/8 in), AVA6-50 (1-1/4 in), AVA7-50 (1-5/8 in) | Corrugated copper outer, copper tube inner, foam PE dielectric | Tower and rooftop feeders, where every tenth of a dB counts |
| HELIAX aluminium | AL5-50 (7/8 in) | Corrugated aluminium outer, copper tube inner | A lighter 7/8 inch feeder |
| HELIAX superflexible (FSJ) | FSJ1-50A (1/4 in), FSJ2-50 (3/8 in), FSJ4-50B (1/2 in), LSF2-50 (3/8 in, sold in jumpers only) | Corrugated copper outer made for a tight bend radius | Jumpers, equipment rooms, any run with tight bends |
| HELIAX special purpose | PTS1-50 (1/4 in, plenum rated, high temperature), heat-treated and phase-stabilised versions of the LDF and FSJ cables (the 35422 part numbers), TS041-50 (4.1 mm) | As the parent cable, with a different dielectric, jacket or treatment | Plenum air spaces and phase-critical systems |
| CNT braided | CNT-300 (0.300 in), CNT-400 (0.400 in) | Tinned copper braid over aluminium tape, copper-clad aluminium inner | Short, flexible runs to routers, repeaters and antennas |
Three things about the part numbers help when you read a quote:
Not everything in service is in the current list. Sites built before the AVA cables often carry LDF5-50A (7/8 inch) and LDF7-50A (1-5/8 inch), and we still supply 5/8 inch LDF4.5RK-50. None of those three series appears in Andrew's list today, where AVA5-50 and AVA7-50 hold the 7/8 and 1-5/8 inch places. The coaxial category we read also holds no air-dielectric cable and no RADIAX radiating cable. We stock RADIAX and cover it under in-building work below.
A coaxial cable has a top frequency, and the bigger the cable the lower that limit sits. This is the first check, because a cable that is not rated for your band is the wrong cable whatever its loss.
| Cable | Size | Operating band | Velocity | Peak power | Minimum bend radius, single / repeated | Weight | Diameter over jacket |
|---|---|---|---|---|---|---|---|
| LDF1-50 | 1/4 in | 1 to 15,800 MHz | 86% | 12.1 kW | 38 / 76 mm | 0.09 kg/m | 8.8 mm |
| LDF2-50 | 3/8 in | 1 to 13,000 MHz | 85% | 15.6 kW | 41 / 95 mm | 0.12 kg/m | 11.2 mm |
| LDF4-50A | 1/2 in | 1 to 8,800 MHz | 88% | 40 kW | 51 / 127 mm | 0.22 kg/m | 15.9 mm |
| AVA5-50 | 7/8 in | 1 to 5,000 MHz | 91% | 91 kW | 127 / 254 mm | 0.45 kg/m | 28.0 mm |
| AL5-50 | 7/8 in | 1 to 5,200 MHz | 88% | 91 kW | 155 / 280 mm | 0.385 kg/m | 28.0 mm |
| AVA6-50 | 1-1/4 in | 1 to 4,000 MHz | 92% | 180 kW | 152 / 203 mm | 0.68 kg/m | 39.6 mm |
| AVA7-50 | 1-5/8 in | 1 to 2,700 MHz | 92% | 302 kW | 203 / 381 mm | 1.07 kg/m | 51.1 mm |
| FSJ1-50A | 1/4 in | 1 to 18,000 MHz | 82% | 6.4 kW | 25 / 25 mm | 0.07 kg/m | 7.4 mm |
| FSJ2-50 | 3/8 in | 1 to 13,400 MHz | 83% | 13.2 kW | 25 / 25 mm | 0.12 kg/m | 10.5 mm |
| FSJ4-50B | 1/2 in | 1 to 10,200 MHz | 81% | 22.5 kW | 32 / 32 mm | 0.21 kg/m | 13.5 mm |
| CNT-300 | 0.300 in | 30 to 6,000 MHz | 83% | 10 kW | 22 mm | 0.06 kg/m | 7.6 mm |
| CNT-400 | 0.400 in | 30 to 6,000 MHz | 85% | 16 kW | 25 mm | 0.10 kg/m | 10.3 mm |
The line to notice is AVA7-50. It is the lowest-loss cable in the range and it stops at 2,700 MHz, so it cannot carry 3.5 GHz 5G. AVA6-50 reaches 4,000 MHz and AVA5-50 reaches 5,000 MHz.
Every cable in the range is 50 ohm, and the HELIAX pages give the tolerance as plus or minus 1 ohm. Radios, antennas, repeaters and test gear for mobile, two-way and microwave work are 50 ohm. Television distribution cable is 75 ohm and is a different product: the two must not be mixed in one run.
Loss rises with frequency and falls with cable size. These are Andrew's figures in dB per 100 m, which Andrew describes as typical and guaranteed within 5%, measured at 20 °C.
| Cable | 150 MHz | 450 MHz | 894 MHz | 1,800 MHz | 2,700 MHz | 3,600 MHz | 6,000 MHz |
|---|---|---|---|---|---|---|---|
| AVA7-50 (1-5/8 in) | 0.80 | 1.44 | 2.11 | 3.16 | 4.02 | not rated | not rated |
| AVA6-50 (1-1/4 in) | 1.02 | 1.83 | 2.67 | 3.96 | 5.02 | 5.96 | not rated |
| AVA5-50 (7/8 in) | 1.43 | 2.55 | 3.69 | 5.44 | 6.85 | 8.08 | not rated |
| AL5-50 (7/8 in) | 1.67 | 2.97 | 4.29 | 6.30 | 7.92 | 9.33 | not rated |
| LDF4-50A (1/2 in) | 2.67 | 4.75 | 6.86 | 10.06 | 12.63 | 14.88 | 20.06 |
| FSJ4-50B (1/2 in) | 4.21 | 7.59 | 11.10 | 16.57 | 21.06 | 25.06 | 34.43 |
| LDF2-50 (3/8 in) | 4.22 | 7.51 | 10.87 | 15.99 | 20.12 | 23.75 | 32.12 |
| FSJ2-50 (3/8 in) | 4.86 | 8.67 | 12.54 | 18.47 | 23.25 | 27.46 | 37.16 |
| CNT-400 (0.400 in) | 4.92 | 8.86 | 12.8 at 900 | 18.4 | 22.0 at 2,500 | 28.9 at 4,000 | 36.42 |
| LDF1-50 (1/4 in) | 4.99 | 8.88 | 12.83 | 18.86 | 23.70 | 27.96 | 37.74 |
| FSJ1-50A (1/4 in) | 7.25 | 12.82 | 18.42 | 26.86 | 33.58 | 39.43 | 52.75 |
| CNT-300 (0.300 in) | not listed | 13.1 | 19.4 at 900 | 28.2 | 33.8 at 2,500 | 44.6 at 4,000 | 55.8 |
Three readings of that table are worth keeping:
Our coax cable loss comparison sets CNT-400 beside LMR-400, RG-58 and RG-213.
Three different limits appear on the datasheets.
Average power is a heating limit. Andrew rates it at 40 °C ambient with the inner conductor at 100 °C, and it falls as frequency rises.
| Cable | Average power at 894 MHz | Average power at 1,800 MHz | Peak power | dc test voltage |
|---|---|---|---|---|
| LDF1-50 | 0.57 kW | 0.39 kW | 12.1 kW | not read |
| LDF2-50 | 0.71 kW | 0.48 kW | 15.6 kW | not read |
| LDF4-50A | 1.11 kW | 0.76 kW | 40 kW | 4,000 V |
| FSJ4-50B | 0.95 kW | 0.64 kW | 22.5 kW | 2,500 V |
| AVA5-50 | 2.27 kW | 1.54 kW | 91 kW | 6,000 V |
| AVA6-50 | 2.46 kW | 1.66 kW | 180 kW | not read |
| AVA7-50 | 3.44 kW | 2.30 kW | 302 kW | 15,000 V |
| CNT-400 | not listed | not listed | 16 kW | 2,500 V |
Peak power and dc test voltage are insulation limits. They matter for pulsed systems such as radar and for high-power broadcast, and hardly at all for a 40 W base station.
RF operating voltage belongs to the connector, and the connector is usually the weakest link. Andrew's L4TNM-PSA, the N male for LDF4-50A, is rated at 707 V rms maximum RF operating voltage, 10 kW peak, 2,000 V dc test and 0.6 kW average at 900 MHz. So a 1/2 inch run with N connectors is a 0.6 kW system at 900 MHz, not the 1.11 kW the cable alone could carry. For high power, choose the cable and the connector interface together.
Return loss says how much of the signal is reflected by the cable itself. Andrew tests each cable in named bands, and the figure only holds in those bands.
| Cable | Tested bands | VSWR / return loss |
|---|---|---|
| LDF4-50A | 680 to 800, 800 to 960, 1,700 to 2,200 and 2,300 to 2,700 MHz | 1.13 / 24.3 dB |
| AVA5-50 | 680 to 800, 800 to 960 and 1,700 to 2,200 MHz | 1.13 / 24.3 dB |
| AVA6-50 and AVA7-50 | 680 to 800, 806 to 960 and 1,700 to 2,170 MHz | 1.13 / 24.3 dB |
| FSJ4-50B | 680 to 800, 800 to 960, 1,700 to 2,200 and 2,300 to 2,700 MHz | 1.20 / 20.8 dB |
| LDF1-50 | 806 to 960 and 1,700 to 2,000 MHz; 4,000 to 6,000 MHz | 1.15 / 23.1 dB; 1.43 / 15.0 dB |
| LDF4P-50A-CBAND | As LDF4-50A, plus 3,450 to 4,200, 4,200 to 4,800 and 5,150 to 5,925 MHz | 19 dB, 16 dB and 16 dB in the three upper bands |
If your system works above 2.7 GHz, the standard LDF4-50A page gives no return loss figure for it. That is what the premium, C-band tested cable is for. The "DOD" in its description is the name of a 5G band, one of the bands the cable is tested in; it is not a defence grade.
The connector has its own figure. The L4TNM-PSA is rated at 38.9 dB to 1,000 MHz, 35 dB to 2,200 MHz, 33 dB to 3,000 MHz, 27 dB to 4,000 MHz and 19 dB to 6,000 MHz.
Andrew rates CNT-400 and CNT-300 at 90 dB shielding effectiveness. The HELIAX cable pages give no figure, because the outer conductor is a continuous metal tube, not a braid; the L4TNM-PSA connector is rated at 130 dB.
Passive intermodulation (PIM) matters where several high-power carriers share one cable, as on a mobile base station. The L4TNM-PSA is rated at -116 dBm third-order intermodulation at 910 MHz with two +43 dBm carriers. Andrew's SureFlex jumpers come in standard, Premium (static PIM) and D-CLASS (dynamic PIM) grades. Braided cable is the usual choice for a single radio, a router or a repeater, and corrugated cable with low-PIM connectors is the usual choice for a multi-carrier base station.
| Cable | Bends it is rated for, minimum / typical | Bending moment | Tensile strength | Flat plate crush |
|---|---|---|---|---|
| LDF4-50A | 15 / 50 | 3.8 N-m | 113 kg | 2.0 kg/mm |
| FSJ4-50B | 20 / 50 | 2.7 N-m | 79 kg | 2.0 kg/mm |
| AVA5-50 | 15 / 30 | 19 N-m | 159 kg | 1.3 kg/mm |
| AVA7-50 | 15 / 50 | 47.5 N-m | 181 kg | 1.6 kg/mm |
| CNT-400 | not listed | not listed | 73 kg | 0.7 kg/mm |
Corrugated copper will take a set, and it work-hardens: it is rated for a number of bends, not for flexing every day. The bending moment tells the rigger how hard the cable is to form. AVA7-50 takes more than twelve times the effort of LDF4-50A, and at 1.07 kg per metre a 60 m run weighs 64 kg before the hoisting grip goes on. CNT-400 has a third of the crush strength of the corrugated cables, so it should not be clamped hard or walked on.
The standard black polyethylene jacket is halogen-free and is not fire-retardant. It is an outdoor jacket. Indoors, in risers and in tunnels, the jacket is chosen by the fire rating the site calls for.
| Jacket | Example | Ratings Andrew lists | Where it goes |
|---|---|---|---|
| Standard PE | LDF4-50A, AVA5-50, FSJ4-50B | None: halogen-free, non-fire-retardant | Outdoors: towers, rooftops, poles |
| RK, non-halogenated fire-retardant polyolefin | LDF4RK-50A | Flame: IEC 60332-1-2, NFPA 130, UL 1666 riser (CATVR/CMR). Smoke: IEC 61034. Acid gas: IEC 60754-1 and -2. Euroclass B2ca-s1a-d1-a1 under EN 50575 | Risers, plant rooms, tunnels, rail and in-building systems |
| Plenum | PTS1-50-P | NFPA 262 (CMP) and UL 910 (CATVP); foam FEP dielectric, fire-retardant PVC jacket | Air-handling ceiling and floor spaces |
| -FR on braided cable | CNT-400-FR, CNT-300A-FR | Non-halogenated fire-retardant polyolefin jacket | In-building tails and jumpers |
Two cautions. The RK jacket narrows the temperature range to -40 to +70 °C, against -55 to +85 °C for the PE cable. And the rating that applies is the one the building's fire engineer, the carrier or the rail authority specifies, so ask for it before ordering.
The HELIAX PE cables are rated for installation from -40 to +60 °C, operation from -55 to +85 °C and storage from -70 to +85 °C. CNT-400 is rated from -40 to +85 °C for installation and operation.
Water does not enter a sound jacket. It enters at the connector, so that is where Andrew publishes its environmental tests. These are the figures for the L4TNM-PSA:
| Test | Method and condition |
|---|---|
| Immersion | 1 m depth, unmated, IEC 60529, IP68 |
| Water jetting | Unmated, IEC 60529, IP66 |
| Moisture resistance | MIL-STD-202F, Method 106F |
| Thermal shock | MIL-STD-202F, Method 107G, Test Condition A-1, low temperature -55 °C |
| Vibration | IEC 60068-2-6 |
| Mechanical shock | MIL-STD-202, Method 213, Test Condition I |
| Corrosion | MIL-STD-1344A, Method 1001.1, Test Condition A |
| Interface durability | 500 matings, IEC 61169-16 |
| Plating | Silver inner contact, trimetal outer contact |
Those tests describe a connector fitted to the right cable with the right tool. A connector fitted to a badly prepared cable passes none of them, which is why the preparation tools further down matter as much as the connector. Outdoors, every joint is then wrapped or cold-shrunk as well. AL5-50 has an aluminium outer conductor, and aluminium and copper behave differently in salt air, so its connectors and sealing should follow Andrew's instructions exactly.
Andrew's cable pages list RoHS and UK RoHS compliance, China RoHS below the maximum concentration value, REACH SVHC compliance against the current list, EN 50575 with a Declaration of Performance available, and manufacture under an ISO 9001:2015 quality system. Connectors differ slightly: the L4TNM-PSA is listed as RoHS "compliant/exempted". If a tender asks for certificates, ask for them by part number.
| Application | Andrew cable | Why |
|---|---|---|
| Mobile tower or rooftop feeder | AVA5-50 for most runs, AVA6-50 or AVA7-50 for long ones, with FSJ4-50B or SureFlex jumpers at each end | Lowest loss and highest power. AVA7-50 only below 2.7 GHz |
| Small cell, short feeder, rooftop link | LDF4-50A | Half the loss of braided cable, light enough to run by hand |
| VHF and UHF two-way radio, repeater sites | LDF4-50A; AVA5-50 on tall masts | At 150 MHz LDF4-50A loses 2.67 dB per 100 m, so a 45 m run costs 1.2 dB |
| Cellular repeater (Cel-Fi GO and similar), router and modem antennas | CNT-400 for short runs; LDF4-50A when the loss budget runs out | Flexible, quick to terminate, 90 dB shielding |
| DAS and in-building coverage | LDF4RK-50A and AVA5RK-50 in risers, FSJ4RK-50B for tails, CNT-400-FR for short drops | The fire-retardant jacket is the deciding feature |
| Tunnels, car parks, lift shafts, long corridors | RADIAX radiating cable: RCT4 (1/2 in, 50 to 3,800 MHz) or RCT5 (7/8 in, 50 to 2,800 MHz) | The cable radiates along its length, so coverage follows the cable |
| Equipment rooms, combiners, test benches | FSJ1-50A, FSJ2-50, LDF1-50, LDF2-50 | Small, tight bends, rated to 13 GHz and above |
| Radar, phased arrays and other phase-critical systems | Phase-stabilised LDF4-50A and FSJ4-50B, heat-treated LDF1, LDF2, FSJ1 and FSJ2 (the 35422 part numbers) | Electrical length that holds with temperature |
| High-temperature or plenum runs | PTS1-50 | Foam FEP dielectric, rated to 20 GHz |
| Military or government communications station (fixed) | AVA5-50 as the standard feeder, AVA7-50 for the longest and highest-power runs, RK versions indoors | Long runs and kilowatt-class transmitters at VHF and UHF |
A tower feeder is chosen on loss, then checked for weight and wind load. The 7/8 inch AVA5-50 is the usual feeder; AVA5-50FX has the same loss at 0.41 kg per metre against 0.45. Long runs at 700 to 2,100 MHz justify AVA6-50 or AVA7-50. The feeder never connects straight to the antenna or the radio: a short superflexible jumper at each end takes the bends and the movement.
Indoors the order of the questions changes: fire rating first, then loss. The RK cables carry riser and low-smoke ratings and a Euroclass under EN 50575, and the same connectors fit them as fit the PE cable of the same size. Where a corridor, tunnel or car park is too long for point antennas, radiating cable replaces them.
A repeater system lives or dies on the donor cable, because loss there cannot be bought back. CNT-400 is right for most donor and server runs. When the run is long, or the band is 3.5 GHz, the table above shows the saving from LDF4-50A. Our antenna guide covers the antennas at each end.
A fixed defence site, such as a communications station, an air base radio site or a radar head, is built like any other fixed radio site, and the same selection method applies. What changes is the emphasis. Runs from the equipment building to the antenna field are long, transmitters are often more powerful, and some systems care about phase as much as loss. Example 7 in the next section works one through. Three parts of the range matter:
What the range is not: it is not a MIL-DTL-17 catalogue. Deployable and vehicle-mounted military radios, and any cable that must meet a military specification by name, need a cable qualified to that specification.
Each example below takes a common job, puts the candidate cables side by side with Andrew's loss figures, and ends with what we would fit and what to order. The percentage beside a loss is the share of the power that reaches the far end of the cable. Connectors and jumpers add a little more loss on top.
Our working rule is to keep a cable run under 3 dB where the site allows it. At 3 dB half the power is gone, in both directions.
| Your job | Worked example |
|---|---|
| Cel-Fi GO or other repeater with a roof antenna | View example |
| 4G or 5G router or modem with an outdoor antenna | View example |
| Mobile tower or rooftop base station feeder | View example |
| 3.5 GHz 5G small cell or fixed wireless | View example |
| VHF or UHF two-way radio repeater | View example |
| In-building coverage (DAS) with risers | View example |
| Military or government communications station | View example |
The job. A donor antenna on the roof feeds a repeater inside, and a second cable runs from the repeater to the indoor antenna. Loss in the donor cable cannot be bought back: every dB lost before the repeater is a dB of weaker signal for it to work with.
| Donor run | CNT-400 at 900 MHz | LDF4-50A at 900 MHz | CNT-400 at 1,800 MHz | LDF4-50A at 1,800 MHz | Our pick |
|---|---|---|---|---|---|
| 10 m | 1.3 dB | 0.7 dB | 1.8 dB | 1.0 dB | CNT-400 |
| 20 m | 2.6 dB | 1.4 dB | 3.7 dB | 2.0 dB | CNT-400; LDF4-50A if the donor signal is weak |
| 30 m | 3.8 dB | 2.1 dB | 5.5 dB | 3.0 dB | LDF4-50A |
| 50 m | 6.4 dB | 3.4 dB | 9.2 dB | 5.0 dB | LDF4-50A |
Recommendation. Up to about 15 m, fit CNT-400: the loss stays under 3 dB at 900 and 1,800 MHz and the cable is easy to route. From 15 to 25 m the choice depends on the donor signal, so measure it first: a strong signal tolerates CNT-400, a marginal one deserves LDF4-50A. Beyond 25 m fit LDF4-50A. The indoor (server) run is usually short, and CNT-400 suits it.
What to order. CNT-400 by the metre with Pulse N-201 connectors, or a made-up Pulse CNT-400 lead. For the longer run, LDF4-50A with two L4TNM-PSA connectors, the MCPT-L4 tool and a 221213 weatherproofing kit for the roof end.
The job. A router or modem indoors, a MIMO antenna outside, and one cable for each antenna port: two runs for a 2x2 router, four for a 4x4. The runs should be the same cable and the same length. On 5G the 3.5 GHz band sets the limit, because loss is highest there.
| Each run | CNT-400 at 900 MHz | CNT-400 at 1,800 MHz | CNT-400 at 3,600 MHz | LDF4-50A at 3,600 MHz | Our pick |
|---|---|---|---|---|---|
| 5 m | 0.6 dB | 0.9 dB | 1.4 dB | 0.7 dB | CNT-400 |
| 10 m | 1.3 dB | 1.8 dB | 2.7 dB | 1.5 dB | CNT-400 |
| 15 m | 1.9 dB | 2.8 dB | 4.1 dB | 2.2 dB | CNT-400 for 4G; LDF4-50A for 3.5 GHz |
| 20 m | 2.6 dB | 3.7 dB | 5.4 dB | 3.0 dB | CNT-400 for 4G; LDF4-50A for 3.5 GHz |
| 30 m | 3.8 dB | 5.5 dB | 8.1 dB | 4.5 dB | LDF4-50A, or move the router |
Recommendation. Keep 3.5 GHz runs in CNT-400 to about 10 m, and 4G-only runs to about 15 m. Past that, either step up to LDF4-50A or shorten the coax: a router mounted near the antenna, with Ethernet run back to the office, loses nothing in the Ethernet. Many outdoor antennas arrive with their own fitted leads, so add the lead's loss to the extension before deciding.
What to order. CNT-400 by the metre or on a 100 m reel, Pulse N-201 and N-200 connectors, the JST-400A stripper and the Pulse RCT-214 crimp tool. Our antenna guide covers the antenna and the router ports.
The job. A base station radio at ground level and a panel antenna 60 m of cable away, on bands from 700 to 2,600 MHz. The feeder is chosen on loss, then checked against the weight and wind load the structure can carry.
| Cable | 60 m at 894 MHz | 60 m at 1,800 MHz | 60 m at 2,700 MHz | Weight of the run | Verdict |
|---|---|---|---|---|---|
| LDF4-50A, 1/2 in | 4.1 dB (39%) | 6.0 dB (25%) | 7.6 dB (17%) | 13 kg | Too lossy for a 60 m main feeder |
| AVA5-50, 7/8 in | 2.2 dB (60%) | 3.3 dB (47%) | 4.1 dB (39%) | 27 kg | The usual choice |
| AVA6-50, 1-1/4 in | 1.6 dB (69%) | 2.4 dB (58%) | 3.0 dB (50%) | 41 kg | When 2.2 dB is too much |
| AVA7-50, 1-5/8 in | 1.3 dB (75%) | 1.9 dB (65%) | 2.4 dB (57%) | 64 kg | Lowest loss; nothing above 2.7 GHz |
Recommendation. Fit AVA5-50. It delivers 60% of the power at 894 MHz against 39% for LDF4-50A, at 27 kg for the run. Move up to AVA6-50 or AVA7-50 when the run is longer, when low-band coverage is the whole point of the site, or when the link budget is tight, and check the structure first: the AVA7-50 run weighs 64 kg. A 2 m FSJ4-50B jumper at each end adds 0.4 dB at 894 MHz and 0.7 dB at 1,800 MHz.
What to order. AVA5-50 by the metre with AL5NM-PSA or 78EZNM N connectors or A5HM-D 4.3-10 connectors, the CPT-78U or 78-HPT tool to suit the connector, SnapStak hangers, an earthing kit for each bonding point and a weatherproofing kit for each outdoor connector. FSJ4-50B or made-up SureFlex jumpers finish each end.
The job. A radio on the 3.5 GHz band with 30 m of feeder to the antenna. Two things change at this frequency: loss is high in every cable, and the biggest cable in the range is not rated for the band at all.
| Cable | 30 m at 3,600 MHz | Power delivered | Verdict |
|---|---|---|---|
| CNT-400 | 8.1 dB | 15% | No: most of the power is lost |
| LDF4-50A, 1/2 in | 4.5 dB | 36% | Acceptable for a low-power radio |
| AVA5-50, 7/8 in | 2.4 dB | 57% | The usual choice |
| AVA6-50, 1-1/4 in | 1.8 dB | 66% | Best loss; rated to 4,000 MHz |
| AVA7-50, 1-5/8 in | Not rated | Not rated | No: rated to 2,700 MHz only |
The CNT-400 figure is interpolated between Andrew's 3,000 and 4,000 MHz values.
Recommendation. Fit AVA5-50, and ask for the version with return loss tested in the band (the premium, C-band cable), because the standard pages quote no return loss above 2,700 MHz. Better still, shorten the feeder: a radio mounted beside the antenna needs only a 2 m FSJ4-50B jumper, which loses 0.5 dB.
What to order. AVA5-50 or AVA6-50 by the metre with 4.3-10 connectors (A5HM-D for AVA5-50), the matching preparation tool, hangers, earthing and weatherproofing as in Example 3.
The job. A land mobile repeater in a hut with its antenna 45 m of cable up a mast, at 150 MHz or 450 MHz. Loss is low at these frequencies, so the case for a big cable is weaker and the case for a cable that lasts on an exposed mast is stronger.
| Cable | 45 m at 150 MHz | 45 m at 450 MHz | Verdict |
|---|---|---|---|
| CNT-400 | 2.2 dB (60%) | 4.0 dB (40%) | Fine for a short, sheltered run |
| LDF4-50A, 1/2 in | 1.2 dB (76%) | 2.1 dB (61%) | The usual choice |
| AVA5-50, 7/8 in | 0.6 dB (86%) | 1.1 dB (77%) | For tall masts and shared sites |
Recommendation. Fit LDF4-50A. It keeps a UHF run to about 2 dB, its solid copper outer conductor does not let water track along a braid, and it takes the low-PIM connectors a shared site needs. Move to AVA5-50 for UHF on runs past about 60 m, or where the repeater shares its antenna through a combiner and every dB is already spoken for.
What to order. LDF4-50A, L4TNM-PSA N male or L4TDM-PSA 7-16 DIN male connectors, the MCPT-L4 tool, SnapStak hangers, a 241088-1 earthing kit for each bonding point and a 221213 weatherproofing kit.
The job. A distributed antenna system in a multi-storey building: a backbone up the riser, a branch along each floor and short tails to the ceiling antennas. Indoors the first question is the fire rating, and the second is loss.
| Cable | 80 m riser at 1,800 MHz | 80 m riser at 3,600 MHz | Weight | Euroclass | Use it for |
|---|---|---|---|---|---|
| LDF4RK-50A, 1/2 in | 8.0 dB | 11.9 dB | 0.25 kg/m | B2ca-s1a-d1-a1 | Floor runs and short risers |
| AVA5RK-50, 7/8 in | 4.4 dB | 6.5 dB | 0.53 kg/m | B2ca-s1a-d2-a1 | The riser backbone |
The RK cables have the same loss as the PE cables of the same size; only the jacket and the temperature range differ.
Recommendation. Run AVA5RK-50 up the riser and LDF4RK-50A along the floors, with FSJ4RK-50B or CNT-400-FR for the last metres to each antenna. Where a corridor, car park or lift lobby is long and narrow, replace the row of antennas with RADIAX radiating cable. Confirm the required fire rating with the building's fire engineer or the carrier before ordering: the rating, not the loss, is what gets a DAS rejected at handover.
What to order. AVA5RK-50 and LDF4RK-50A by the metre, FSJ4RK-50B for tails, CNT-400-FR for short drops, and RCT4 or RCT5 radiating cable. The connectors and tools are the same as for the PE cable of the same size.
The job. A fixed station with VHF and UHF radios in an equipment building and an antenna field 100 m of cable away. Transmitters run from tens of watts to a kilowatt or more, several services share the site, and some antennas are arrays that depend on phase.
| Cable | 100 m at 150 MHz | 100 m at 450 MHz | Average power rating at 150 / 450 MHz | Use it for |
|---|---|---|---|---|
| LDF4-50A, 1/2 in | 2.7 dB (54%) | 4.7 dB (34%) | 2.85 kW / 1.61 kW | Short runs and receive-only antennas |
| AVA5-50, 7/8 in | 1.4 dB (72%) | 2.6 dB (56%) | 5.86 kW / 3.29 kW | The general-purpose feeder |
| AVA7-50, 1-5/8 in | 0.8 dB (83%) | 1.4 dB (72%) | 9.09 kW / 5.04 kW | Longest runs and highest power |
Recommendation. Fit AVA5-50 as the standard feeder: it delivers 72% of the power at 150 MHz and 56% at 450 MHz over 100 m, and is rated above 3 kW average at 450 MHz. Use AVA7-50 for the longest runs and the highest-power transmitters, remembering that the connector, not the cable, usually sets the power limit. Inside buildings and cable tunnels, use the RK fire-retardant versions. For direction-finding and phased arrays, ask for the phase-stabilised cables and for a phase figure against your temperature range. If the contract names a military cable specification, that specification governs and this range may not qualify.
What to order. AVA5-50 or AVA7-50 by the metre or on a drum, AL5NM-PSA or AL7NM-PSA connectors, the CPT-78U or A7-EZPT tool, a hoisting grip for the 1-5/8 inch cable, and earthing and weatherproofing at every outdoor joint.
These are projects where the supplier or the trade press named the cable.
| Use | Project | What was installed |
|---|---|---|
| Mobile network build | China Telecom CDMA network, 2008 | Base station antennas with HELIAX cable and accessories, for part of a build of about 15,000 sites |
| Mobile network build | Powertel, south-eastern United States, 1999 | HELIAX cable with its connectors, SureFlex jumpers and earthing kits, and EASIAX preparation tools to speed installation across 12 states |
| Mobile network build | Tata Teleservices, India | HELIAX FXL smooth-wall feeder cable at new base station sites |
| Television broadcast | Two Tulsa TV stations, 2018 | HELIAX flexible transmission line between the transmitters and new antennas on a city building |
| Rail | Kowloon-Canton Railway West Rail, Hong Kong | RADIAX radiating cable with HELIAX coaxial cable and connectors, in nine stations and along part of the track |
| Rail tunnel | Gotthard Base Tunnel, Switzerland | RADIAX radiating cable with a fibre-fed distributed antenna system, through the rail tubes and 153 km of access and service tunnels |
| Utility tunnel | Ausgrid cable tunnel, Sydney | RADIAX fixed to the ceiling of a 4 m diameter tunnel during construction, for two-way radio between tunnel and surface crews |
The Powertel order is the pattern to copy on any job: the cable, its connectors, the jumpers, the earthing kits and the preparation tools were bought as one system.
A HELIAX connector is made for one cable. The first characters name it: L4 fits LDF4, F4 fits FSJ4, and a 7/8 inch connector for AVA5 will not go on LDF4.
Andrew L4TNM-PSA, N male for LDF4-50A
Andrew 400BPNM-C, N male for CNT-400
Pulse N-201, N male for CNT-400
Pulse N-200, N female for CNT-400
| Cable | Andrew connectors we stock | Pulse alternative |
|---|---|---|
| CNT-400 | 400BPNM-C N male, 400BPNF-C N female, 400APNM-CS8 N male, 400PSM-CR SMA male, with TNC, BNC and 7-16 DIN versions | Pulse N-201 N male and Pulse N-200 N female (captive pin, crimp), N-205 N male (solder or crimp), D43-111 4.3-10 male |
| LDF1-50 | L1TNM-PL N male | |
| LDF2-50 | L2TNM-PL N male | |
| LDF4-50A and LDF4RK-50A | L4TNM-PSA N male, L4TNF-PSA N female, L4TDM-PSA 7-16 DIN male, L4HM-D 4.3-10 male | |
| FSJ1-50A | F1TNM-HC N male | |
| FSJ2-50 | F2TNM-PL N male | |
| FSJ4-50B | F4PNMV2-HC N male, F4HM-D 4.3-10 male | |
| AVA5-50 and AVA5-50FX | AL5NM-PSA N male, 78EZNM EZfit N male, A5HM-D 4.3-10 male | |
| AVA6-50 | 114EZNM EZfit N male, A6HM-S 4.3-10 male | |
| AVA7-50 | AL7NM-PSA N male, A7HM-S 4.3-10 male |
The Pulse N-201 and N-200 are the connectors most CNT-400 leads leave our bench with. They crimp with the Pulse RCT-214 tool, and we also sell made-up Pulse CNT-400 leads in 10, 15 and 20 m lengths. Our guides to which connector goes with which cable and to compression, crimp and solder connectors go further.
On interface: N is the general-purpose choice, 7-16 DIN is the older high-power base station interface, and 4.3-10 is the current low-PIM interface on mobile equipment.
Corrugated cable is cut, stripped and flared to exact lengths before the connector goes on. The tool is specific to the cable and to the connector series.
Andrew MCPT-L4 manual tool
Andrew CPT-L4ARC1 automated tool
JST-400A stripper for CNT-400
Pulse RCT-214 crimp tool
| Cable | Tool | Type | Prepares the cable for |
|---|---|---|---|
| LDF4-50A | MCPT-L4 | Manual | PSA and F-Class connectors |
| LDF4-50A | CPT-L4ARC1 | Automated, drill driven | PSA, PS, C and BHC connectors |
| LDF4-50A | CPT-L4-D | Automated | D-Class connectors |
| LDF4-50A | L4310-GT | Manual | S-Class, HM-F and HF-F connectors |
| FSJ1-50A | CPT-F1-D | Automated | D-Class connectors |
| FSJ2-50 | CPT-F2-D | Automated | D-Class connectors |
| FSJ4-50B | CPT-F4-D, CPT-F4B | Automated | D-Class connectors; FSJ4-50B generally |
| AVA5-50 | CPT-78U | Automated | PSA connectors |
| AVA5-50 | 78-HPT | Manual | EZfit, S-Class and F-Class connectors |
| AVA5-50 and AVA5-50FX | A5FX-EZPT | Automated | EZfit connectors |
| AVA6-50 | CPT-114U, A6-EZPT | Automated | PSA connectors; EZfit connectors |
| AVA7-50 | A7-EZPT | Automated | EZfit connectors |
| CNT-400 | JST-400A jacket stripper, Pulse RCT-214 crimp tool | Manual | Crimp connectors |
Buy the tool with the first connectors. A hacksaw and a knife will get a connector onto LDF4-50A, and the return loss and the water seal will both show it.
Andrew 221213 weatherproofing kit
Earthing kit 241088-1, 1/2 inch
SnapStak hanger, 1/2 inch
Click-on hanger, 1/2 inch
The full range is in our coaxial cables, CommScope, Pulse and RF connectors collections.
Yes. Andrew was part of CommScope from 2007, and since February 2025 it has been ANDREW, an Amphenol company. HELIAX, CNT and RADIAX part numbers did not change.
Both are 1/2 inch, 50 ohm HELIAX. LDF4-50A is the feeder: 6.86 dB per 100 m at 894 MHz and a 127 mm repeated bend radius. FSJ4-50B is the jumper: 11.10 dB per 100 m and a 32 mm bend radius. They take different connectors.
No. Andrew rates AVA7-50 from 1 to 2,700 MHz. Use AVA6-50 (to 4,000 MHz) or AVA5-50 (to 5,000 MHz).
As long as the loss budget allows. At 900 MHz CNT-400 loses 12.8 dB per 100 m, so 3 dB, half the power, is gone in about 23 m. At 1,800 MHz that point comes at about 16 m. Beyond it, move to LDF4-50A.
In risers, plant rooms, tunnels and rail environments, almost always. The standard PE jacket is not fire-retardant. The RK cables carry the flame, smoke and acid gas ratings, and the site's fire specification says which rating is required.
Yes. The Pulse N-201 and N-200 are made for CNT-400, and several Pulse connectors list CNT-400 and LMR-400 together.
It needs the preparation tool made for that cable and connector series. The connector's return loss and its IP68 seal both depend on the cut.
Send us the frequency, the run length, the power and where the cable goes (tower, riser, tunnel, cabinet), and we will come back with the cable, the connectors, the tool and the weatherproofing as one list, cut to length or on a drum.